This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 9.8. The following CVEs are assigned: CVE-2023-5402.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 9.8. The following CVEs are assigned: CVE-2023-5402.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 9.8. The following CVEs are assigned: CVE-2023-5399.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 9.8. The following CVEs are assigned: CVE-2023-5399.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command.
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CBZ files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CBZ files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose information in the context of SYSTEM.
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose information in the context of SYSTEM.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric C-Bus Toolkit. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of commands sent to the C-Gate 2 Service. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.