A vulnerability was found in Tenda A15 15.13.07.13. Affected is the function fromSetWirelessRepeat of the file /goform/openNetworkGateway. The manipulation of the argument wpapskcrypto24g results in buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
A vulnerability was found in Tenda AC15 15.03.05.19multi and classified as critical. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC15 15.03.05.19multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC15 15.03.05.19multi. It has been declared as critical. This vulnerability affects the function formsetschedled of the file /goform/SetLEDCf of the component HTTP POST Request Handler. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC15 15.03.05.19multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda A15 15.13.07.09/15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/multimodalAdd of the component HTTP POST Request Handler. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC15 up to 15.03.05.19 and classified as critical. This issue affects the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument mac leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A buffer overflow vulnerability has been discovered in Tenda Ac15 V15.13.07.13. The vulnerability occurs when the webCgiGetUploadFile function calls the socketRead function to process HTTP request messages, resulting in the overwriting of a buffer on the stack.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepauth parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security5g parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd5g parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey4 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn5g parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey2 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd parameter at /goform/WifiBasicSet.
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey1 parameter at /goform/WifiBasicSet.
In Tenda AC15 V15.03.05.19, the function "henanpppoeuser" contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, the function "sub8EE8" contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, the function "subED14" contains a stack-based buffer overflow vulnerability.
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, the function "xianpppoeuser" contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, The function "xkjsver32" contains a stack-based buffer overflow vulnerability.