CVE-2021-34329: Siemens JT2Go PAR File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability

Published Jul 13, 2021
·
Updated

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)

Other sources

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PAR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Affected Software

11 affected componentsFixes available
Siemens JT2Go<13.2
13.2
Siemens Teamcenter Visualization<13.2
13.2
Siemens JT2Go
Siemens JT2Go<13.2.0
Siemens Solid Edge<se2021
Siemens Solid Edge=se2021
Siemens Solid Edge=se2021-maintenance_pack1
Siemens Solid Edge=se2021-maintenance_pack2
Siemens Solid Edge=se2021-maintenance_pack3
Siemens Solid Edge=se2021-maintenance_pack4
Siemens Teamcenter Visualization<13.2.0

Event History

Jul 13, 2021
CVE Published
via MITRE·11:03 AM
Data Sourced
via MITRE·11:03 AM
DescriptionWeakness
Aug 4, 2024
Advisory Published
via ZDI·12:16 AM

Parent advisories

This vulnerability appears in the following advisories.

Frequently Asked Questions

1

What is the vulnerability ID of this Siemens JT2Go vulnerability?

The vulnerability ID is CVE-2021-34329.

2

What is the severity of CVE-2021-34329?

The severity of CVE-2021-34329 is high with a CVSS score of 7.8.

3

How does the vulnerability in Siemens JT2Go work?

The vulnerability in Siemens JT2Go is a heap-based buffer overflow that allows remote attackers to execute arbitrary code.

4

What software versions are affected by CVE-2021-34329?

Siemens JT2Go up to and excluding version 13.2.0 is affected.

5

Are there any references for more information about CVE-2021-34329?

Yes, you can find more information about CVE-2021-34329 at the following references: US-CERT advisory (https://us-cert.cisa.gov/ics/advisories/icsa-21-194-15), Siemens product cert (https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf), and Zero Day Initiative advisory (https://www.zerodayinitiative.com/advisories/ZDI-21-867/).

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.