First published: Tue Nov 21 2023(Updated: )
The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Credit: ics-cert@hq.dhs.gov
Affected Software | Affected Version | How to fix |
---|---|---|
Siemens JT2Go | <13.2.0.7 | |
Siemens Teamcenter Visualization | >=13.1.0<13.1.0.8 | |
Siemens Teamcenter Visualization | >=13.2.0<13.2.0.7 | |
Siemens Teamcenter Visualization | =13.3.0 | |
Siemens JT2Go | <13.2.0.7 | 13.2.0.7 |
Siemens Teamcenter Visualization v13.2 | <13.2.0.7 | 13.2.0.7 |
Siemens Solid Edge SE2021: All versions prior to SE2021MP9 | ||
Siemens Solid Edge SE2022: All versions prior to SE2022MP1 | ||
Siemens Teamcenter Visualization v12.4 | <12.4.0.13 | 12.4.0.13 |
Siemens has released updates for some of the affected products and recommends updating to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not yet available. * JT2Go: Update to v13.2.0.7 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html or later version * Teamcenter Visualization v13.1: Update to v13.1.0.9 or later version https://support.sw.siemens.com/ * Teamcenter Visualization v13.2: Update to v13.2.0.7 or later version https://support.sw.siemens.com/ * Teamcenter Visualization v13.3: Update to v13.3.0.1 or later version https://support.sw.siemens.com/ Please see Siemens security advisory SSA-301589 https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf for more information.
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
The vulnerability ID for this Siemens Solid Edge JT2Go and Teamcenter Visualization vulnerability is CVE-2021-38405.
The severity of CVE-2021-38405 is rated as high with a CVSS score of 7.8.
CVE-2021-38405 is a vulnerability in Siemens Solid Edge JT2Go and Teamcenter Visualization that allows an attacker to execute code within the context of the current process by exploiting a memory corruption issue.
Siemens JT2Go versions up to and excluding 13.2.0.7, and Siemens Teamcenter Visualization versions 13.1.0 up to and excluding 13.1.0.8, 13.2.0 up to and excluding 13.2.0.7, and exactly 13.3.0 are affected by CVE-2021-38405.
Apply the necessary updates provided by Siemens to address the vulnerability in Siemens Solid Edge JT2Go and Teamcenter Visualization.