First published: Tue Nov 08 2022(Updated: )
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)
Credit: productcert@siemens.com
Affected Software | Affected Version | How to fix |
---|---|---|
Siemens Parasolid | >=34.0.252<34.0.254 | |
Siemens Parasolid | >=34.1.242<34.1.244 | |
Siemens Parasolid | >=35.0.170<35.0.184 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
The vulnerability ID is CVE-2022-39157.
The affected software is Siemens Parasolid versions < V34.0.252, >= V34.0.252 < V34.0.254, < V34.1.242, >= V34.1.242 < V34.1.244, < V35.0.170.
The severity of CVE-2022-39157 is high with a severity value of 7.8.
Updating to a version higher than V34.0.254, V34.1.244, or V35.0.170 will fix this vulnerability.
You can find more information about CVE-2022-39157 at the following references: [SSA-565356.pdf](https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf) and [SSA-853037.pdf](https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf).