First published: Tue Feb 11 2025(Updated: )
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
Credit: productcert@siemens.com
Affected Software | Affected Version | How to fix |
---|---|---|
Siemens SIPROTEC 5 | <V9.90 | |
Siemens 6md85 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 6MD86 firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 6MD89 firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 6MU85 Firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7KE85 Firmware | >=V8.80 | |
Siemens SIPROTEC 5 | <V9.90 | |
Siemens SIPROTEC 5 7SA86 Firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7SA87 Firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 Firmware | <V9.90 | |
Siemens SIPROTEC 5 7SD86 firmware | >=V8.80<V9.90 | |
Siemens 7SD87 | >=V8.80<V9.90 | |
siemens SIPROTEC compact model 7sj81 | <V9.90 | |
Siemens SIPROTEC 5 Firmware | <V9.90 | |
Siemens SIPROTEC 5 7SJ85 firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7SJ86 (CP300) | >=V8.80<=undefined | |
Siemens SIPROTEC 5 7SK82 Firmware | <V9.90 | |
Siemens SIPROTEC 5 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7SL82 Firmware | <V9.90 | |
Siemens SIPROTEC 5 7SL86 firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7SL87 (CP200) | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7ST85 (CP300) | >=V8.80 | |
Siemens SIPROTEC 5 | =All versions | |
Siemens SIPROTEC 5 | <V9.90 | |
Siemens SIPROTEC 5 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 | <V9.90 | |
Siemens 7UM85 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7UT82 firmware | <V9.90 | |
Siemens SIPROTEC 5 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7UT86 (CP200) | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7UT87 firmware | >=V8.80<V9.90 | |
siemens SIPROTEC 5 7VE85 firmware | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 7VK87 | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 | <V9.90 | |
Siemens SIPROTEC 5 Communication Module ethba2el firmware | <V9.90 | |
Siemens SIPROTEC 5 Communication Module ETH-BB-2FO | <V9.90 | |
Siemens SIPROTEC 5 Communication Module ETH-BD-2FO | >=V8.80<V9.90 | |
Siemens SIPROTEC 5 Compact 7SX800 | >=V9.50<V9.90 |
Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.
CVE-2024-54015 has a critical severity level, requiring immediate attention due to the potential for significant impact on affected systems.
To fix CVE-2024-54015, you should upgrade all affected Siemens SIPROTEC 5 devices to version V9.90 or later.
CVE-2024-54015 affects all versions of SIPROTEC 5 6MD84, 6MD85, 6MD86, 6MD89, and several others prior to version V9.90.
No, it is not advisable to ignore CVE-2024-54015 as it poses critical security risks that could be exploited.
CVE-2024-54015 impacts various Siemens SIPROTEC 5 devices, including models 6MD84, 6MD85, 6MD86, and others in the series.