Where
-Infinity
0
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

For certain systems running EOS, a Precision Time Protocol (PTP) packet of a management/signaling message with an invalid Type-Length-Value (TLV) causes the PTP agent to restart. Repeated restarts of the service will make the service unavailable.

Remedy

The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Artista recommends customers move to the latest version of each release that contains all the fixes listed below. CVE-2021-28510 has been fixed in the following releases: 4.27.2 and later releases in the 4.27.x train 4.26.5 and later releases in the 4.26.x train 4.25.7 and later releases in the 4.25.x train 4.24.9 and later releases in the 4.24.x train 4.23.11 and later releases in the 4.23.x train

Remedy

Hotfix The following hotfix can be applied to remediate CVE-2021-28510 Note: Installing/uninstalling the SWIX will cause the PTP agent to restart. Version: 1.0 URL:SecurityAdvisory76_CVE-2021-28510_Hotfix.swix SWIX hash: (SHA-512)2b78b8274b7c73083775b0327e13819c655db07e22b80038bb3843002c679a798b53a4638c549a86183e01a835377bf262d27e60020a39516a5d215e2fadb437
First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

On affected platforms running Arista EOS with SNMP configured, a specially crafted packet can cause a memory leak in the snmpd process. This may result in the snmpd processing being terminated (causing SNMP requests to time out until snmpd is automatically restarted) and potential memory resource exhaustion for other processes on the switch. The vulnerability does not have any confidentiality or integrity impacts to the system.

Remedy

The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Artista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see Eos User Manual: Upgrades and Downgrades CVE-2023-24511 has been fixed in the following releases: 4.29.2F and later releases in the 4.29.x train 4.28.6M and later releases in the 4.28.x train 4.27.9M and later releases in the 4.27.x train 4.26.10M and later releases in the 4.26.x train

Remedy

The following hotfix can be applied to remediate CVE-2023-24511. The hotfix only applies to the releases listed below and no other releases. All other versions require upgrading to a release containing the fix (as listed above).: 4.29.1F and below releases in the 4.29.x train 4.28.5.1M and below releases in the 4.28.x train 4.27.8.1M and below releases in the 4.27.x train 4.26.9M and below releases in the 4.26.x train Note: Installing/uninstalling the SWIX will cause the snmpd process to restart Version: 1.0 URL:SecurityAdvisory84_CVE-2023-24511_Hotfix.swix SWIX hash:SecurityAdvisory84_CVE-2023-24511_Hotfix.swix (SHA-512)da2bc1fd2c7fc718e3c72c7ce83dc1caa05150cbe2f081c8cc3ed40ce787f7e24dff5202e621ef5f2af89f72afd25f7476d02f722ffe8e8c7d24c101cbbfe0e5
First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

On the affected platforms running EOS, a malformed DHCP packet might cause the DHCP relay agent to restart.

Remedy

CVE-2023-24510 has been fixed in the following releases: - 4.29.2F and later releases in the 4.29.x train - 4.28.7M and later releases in the 4.28.x train - 4.27.10M and later releases in the 4.27.x train - 4.26.10M and later releases in the 4.26.x train
First published (updated )
Severity
5.3
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

In Arista EOS malformed packets can be incorrectly forwarded across VLAN boundaries in one direction. This vulnerability is only susceptible to exploitation by unidirectional traffic (ex. UDP) and not bidirectional traffic (ex. TCP). This affects: EOS 7170 platforms version 4.21.4.1F and below releases in the 4.21.x train; EOS X-Series versions 4.21.11M and below releases in the 4.21.x train; 4.22.6M and below releases in the 4.22.x train; 4.23.4M and below releases in the 4.23.x train; 4.24.2.1F and below releases in the 4.24.x train.

First published (updated )
Severity
8.8
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N

On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.