In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI.
In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty after reboot .
In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface.
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable.