Severity
7.8
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

A vulnerability in the logging configuration of Secure Sockets Layer (SSL) policies for Cisco FirePOWER System Software 5.3.0 through 6.2.2 could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to high consumption of system resources. The vulnerability is due to the logging of certain TCP packets by the affected software. An attacker could exploit this vulnerability by sending a flood of crafted TCP packets to an affected device. A successful exploit could allow the attacker to cause a DoS condition. The success of an exploit is dependent on how an administrator has configured logging for SSL policies for a device. This vulnerability affects Cisco FirePOWER System Software that is configured to log connections by using SSL policy default actions. Cisco Bug IDs: CSCvd07072.

First published (updated )
Severity
8.2
OS Command Injection
CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203