Where
-Infinity
0
Severity
8.6
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

A vulnerability in the processing of SSH connections for multi-instance deployments of Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. This vulnerability is due to a lack of proper error handling when an SSH session fails to be established. An attacker could exploit this vulnerability by sending a high rate of crafted SSH connections to the instance. A successful exploit could allow the attacker to cause resource exhaustion, which causes a DoS condition on the affected device. The device must be manually reloaded to recover.

First published (updated )
Severity
6.1
XSS
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an attacker to execute a cross-site scripting (XSS) attack or an open redirect attack. For more information about these vulnerabilities, see the Details section of this advisory.

First published (updated )
Severity
4.8
XSS
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an attacker to execute a cross-site scripting (XSS) attack or an open redirect attack. For more information about these vulnerabilities, see the Details section of this advisory.

First published (updated )
Severity
8.1
Path Traversal, Input Validation
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to perform a directory traversal attack on an affected device. The attacker would require valid device credentials. The vulnerability is due to insufficient input validation of the HTTPS URL by the web-based management interface. An attacker could exploit this vulnerability by sending a crafted HTTPS request that contains directory traversal character sequences to an affected device. A successful exploit could allow the attacker to read or write arbitrary files on the device.

First published (updated )
Severity
6
AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N

A vulnerability in Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to overwrite or append arbitrary data to system files using root-level privileges. The attacker must have administrative credentials on the device. This vulnerability is due to incomplete validation of user input for a specific CLI command. An attacker could exploit this vulnerability by authenticating to the device with administrative privileges and issuing a CLI command with crafted user parameters. A successful exploit could allow the attacker to overwrite or append arbitrary data to system files using root-level privileges.

First published (updated )
Severity
7.8
OS Command Injection, Input Validation
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Multiple vulnerabilities in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to execute arbitrary commands with root privileges. For more information about these vulnerabilities, see the Details section of this advisory.

First published (updated )
Severity
7.8
OS Command Injection, Input Validation
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Multiple vulnerabilities in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to execute arbitrary commands with root privileges. For more information about these vulnerabilities, see the Details section of this advisory.

First published (updated )
Severity
5.4
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

A vulnerability in the web-based management interface of Cisco Firepower Management Center could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected device. An attacker could exploit this vulnerability by first entering input within the web-based management interface and then persuading a user of the interface to view the crafted input within the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.

First published (updated )
Severity
9
AV:N/AC:L/Au:S/C:C/I:C/A:C

The web-based management interfaces in Sourcefire Defense Center (DC) and 3D Sensor before 4.8.2 allow remote authenticated users to gain privileges via a $admin value for the admin parameter in an edit action to admin/user/user.cgi and unspecified other components.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203