Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
CNCSoft: All versions prior to 1.01.32 does not properly sanitize input while processing a specific project file, allowing a possible stack-based buffer overflow condition.
Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
Delta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-1595.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-1595.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-1941.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-1941.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2023-4685.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2023-4685.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.