Where
-Infinity
0
Severity
9
XSS, Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H

The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully compromised.

1 / 2
Source: MITRE

Remedy

Delta Electronics patched this vulnerability in Version 1.5.0.12 https://downloadcenter.deltaww.com/en-US/DownloadCenter  and recommends all users update device firmware to that version or later.
First published (updated )
Severity
8.8
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Command Injection via lform/netdiagnose.

First published (updated )
Severity
5.4
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Cross Site Scripting (XSS) via lform/urlfilter.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203