Where
AND
AND
-Infinity
0
Severity
4.3
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

On BIG-IP 11.5.1-11.6.3.4, 12.1.0-12.1.3.7, 13.0.0-13.1.1.3, and 14.0.0-14.0.0.2, when processing certain SNMP requests with a request-id of 0, the snmpd process may leak a small amount of memory.

First published (updated )
Severity
4.3
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

In BIG-IP 14.0.0-14.0.0.2, 13.0.0-13.1.0.7, 12.1.0-12.1.3.5, 11.6.1-11.6.3.2, or 11.5.1-11.5.8 or Enterprise Manager 3.1.1, malformed requests to the Traffic Management User Interface (TMUI), also referred to as the BIG-IP Configuration utility, may lead to disruption of TMUI services. This attack requires an authenticated user with any role (other than the No Access role). The No Access user role cannot login and does not have the access level to perform the attack.

First published (updated )
Severity
6.1
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

In BIG-IP 14.0.0-14.0.0.2, 13.0.0-13.1.1.3, 12.1.0-12.1.3.7, 11.6.1-11.6.3.2, or 11.5.1-11.5.8, when remote authentication is enabled for administrative users and all external users are granted the "guest" role, unsanitized values can be reflected to the client via the login page. This can lead to a cross-site scripting attack against unauthenticated clients.

First published (updated )
Severity
6.1
XSS
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

On BIG-IP 14.0.0-14.0.0.2, 13.0.0-13.1.1.3, 12.1.0-12.1.3.7, and 11.6.0-11.6.3.2, a reflected Cross Site Scripting (XSS) vulnerability is present in an undisclosed page of the BIG-IP TMUI (Traffic Management User Interface) also known as the BIG-IP configuration utility.

First published (updated )
Severity
5.5
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N

When BIG-IP 14.0.0-14.0.0.2, 13.0.0-13.1.0.5, 12.1.0-12.1.3.5, 11.6.0-11.6.3.2, or 11.2.1-11.5.6, BIG-IQ Centralized Management 5.0.0-5.4.0 or 4.6.0, BIG-IQ Cloud and Orchestration 1.0.0, iWorkflow 2.1.0-2.3.0, or Enterprise Manager 3.1.1 is licensed for Appliance Mode, Admin and Resource administrator roles can by-pass BIG-IP Appliance Mode restrictions to overwrite critical system files. Attackers of high privilege level are able to overwrite critical system files which bypasses security controls in place to limit TMSH commands. This is possible with an administrator or resource administrator roles when granted TMSH. Resource administrator roles must have TMSH access in order to perform this attack.

First published (updated )
Severity
4.3
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

In BIG-IP 14.0.0-14.0.0.2 or 13.0.0-13.1.1.1, iControl and TMSH usage by authenticated users may leak a small amount of memory when executing commands

First published (updated )
Severity
5.9
Input Validation
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

On BIG-IP 14.0.0-14.0.0.2 or 13.0.0-13.1.1.1, in certain circumstances, when processing traffic through a Virtual Server with an associated MQTT profile, the TMM process may produce a core file and take the configured HA action.

First published (updated )
Severity
6.5
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

On BIG-IP 14.0.0-14.0.0.2, 13.0.0-13.1.0.7, 12.1.0-12.1.3.5, 11.6.0-11.6.3.2, or 11.2.1-11.5.6, BIG-IQ Centralized Management 6.0.0-6.0.1, 5.0.0-5.4.0 or 4.6.0, BIG-IQ Cloud and Orchestration 1.0.0, iWorkflow 2.0.1-2.3.0, or Enterprise Manager 3.1.1 a BIG-IP user granted with tmsh access may cause the BIG-IP system to experience denial-of-service (DoS) when the BIG-IP user uses the tmsh utility to run the edit cli preference command and proceeds to save the changes to another filename repeatedly. This action utilises storage space on the /var partition and when performed repeatedly causes the /var partition to be full.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203