Juniper JUNOSJunos OS: MX Series: PFE crash upon receipt of specific packet destined to an AMS interface

7.5
First published (updated )

Juniper JUNOSSRX Series and MX Series: An FPC core is observed when IDP is enabled on the device and a specific malformed SSL packet is received

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series: The FPC will crash on receiving a malformed CFM packet

First published (updated )

Juniper JUNOSJunos OS: MX Series: An MPC will crash upon receipt of a malformed CFM packet.

First published (updated )

Juniper JUNOSJunos OS: SRX Series and MX Series: SIP ALG doesn't drop specifically malformed retransmitted SIP packets

7.5
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Juniper JUNOSJunos OS: MX Series: In a PTP scenario a prolonged routing protocol churn can trigger an FPC reboot

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series: An FPC crash is observed when CFM is enabled in a VPLS scenario and a specific LDP related command is run

First published (updated )

Juniper JUNOSJunos OS: MX Series: The bbe-smgd process crashes if an unsupported configuration exists and a PPPoE client sends a specific message

First published (updated )

Juniper JUNOSJunos OS: User-defined ARP Policer isn't applied on Aggregated Ethernet (AE) interface until firewall process is restarted

First published (updated )

Juniper JUNOSJunos OS: MX MS-MPC or MS-MIC, or SRX SPC crashes if it receives a SIP message with a specific contact header format

7.5
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Juniper JUNOSJunos OS: MX Series: An FPC crash might be seen due to mac-moves within the same bridge domain

First published (updated )

Juniper JUNOSJunos OS: MX Series, EX9200 Series: FPC may crash upon receipt of specific MPLS packet affecting Trio-based MPCs

First published (updated )

Juniper JUNOSSRX Series and MX Series with SPC3: A high percentage of fragments might lead to high latency or packet drops

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series: Denial of Service vulnerability in MS-PIC component on MS-MIC or MS-MPC

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series: In BBE configurations, receipt of a specific MPLS or IPv6 packet causes a Denial of Service

7.8
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Juniper JUNOSJunos OS: MX Series: Receipt of specific packet on MS-MPC/MS-MIC causes line card reset

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series, EX9200 Series: Trio-based MPCs memory leak in VPLS with integrated routing and bridging (IRB) interface

First published (updated )

Juniper JUNOSJunos OS and Junos OS Evolved: Trio Chipset: Denial of Service due to packet destined to device's interfaces.

First published (updated )

Juniper JUNOSJunos OS: MX Series: jdhcpd crash when receiving a specific crafted DHCP response message

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series with MPC11: In a GNF / node slicing scenario gathering AF interface statistics can lead to a kernel crash

7.5
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Juniper JUNOSJunos OS: MX Series: MPC 7/8/9/10/11 cards with MAP-E: PFE halts when an attacker sends malformed IPv4 or IPv6 traffic inside the MAP-E tunnel.

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series, EX9200 Series, SRX4600: Ethernet interface vulnerable to specially crafted frames

First published (updated )

Juniper JUNOSJunos OS and Junos OS Evolved: MX Series with MPC10/MPC11, PTX10003, PTX10008: Line card may crash and restart when traffic is hitting a firewall filter having a term with syslog action configured

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series and SRX Series: The flowd daemon will crash if the SIP ALG is enabled and specific SIP messages are processed

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC: The BRAS Subscriber Services service activation portal is vulnerable to a Denial of Service (DoS) via malformed HTTP packets

8.6
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Juniper JUNOSJunos OS: vMX series: Predictable IP ID sequence numbers vulnerability

First published (updated )

Juniper JUNOSJunos OS: MX Series and SRX Series: When receiving a specific SIP packets stale call table entries are created which eventually leads to a DoS for all SIP traffic

First published (updated )

Juniper JUNOSNull Pointer Dereference

7.5
First published (updated )

Juniper JUNOSJunos OS: MX Series: Traffic drops will be observed if MS-MPC/MS-PIC resources are consumed by certain traffic causing a partial DoS

First published (updated )

Juniper JUNOSJunos OS: MX Series: In subscriber management / BBE configuration authd can crash if a subscriber with a specific username tries to login leading to a DoS

First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2024 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203