Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash and disruption to USB communication.
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.