Where
-Infinity
0
Severity
8.8
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Certain NETGEAR smart switches are affected by a \n injection in the web UI's password field, which - due to several faulty aspects of the authentication scheme - allows the attacker to create (or overwrite) a file with specific content (e.g., the "2" string). This leads to admin session crafting and therefore gaining full web UI admin privileges by an unauthenticated attacker. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS750E before 1.0.1.10, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

First published (updated )
Severity
7.8
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Certain NETGEAR smart switches are affected by an authentication hijacking race-condition vulnerability by an unauthenticated attacker who uses the same source IP address as an admin in the process of logging in (e.g., behind the same NAT device, or already in possession of a foothold on an admin's machine). This occurs because the multi-step HTTP authentication process is effectively tied only to the source IP address. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS750E before 1.0.1.10, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

First published (updated )
Severity
9.8
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Certain NETGEAR smart switches are affected by a remote admin password change by an unauthenticated attacker via the (disabled by default) /sqfs/bin/sccd daemon, which fails to check authentication when the authentication TLV is missing from a received NSDP packet. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS750E before 1.0.1.10, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

First published (updated )
Severity
6
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N

Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1.

First published (updated )
Severity
10
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker via the vulnerable /sqfs/lib/libsal.so.0.0 library used by a CGI application, as demonstrated by setup.cgi?token=';$HTTPUSERAGENT;' with an OS command in the User-Agent field. This affects GC108P before 1.0.7.3, GC108PP before 1.0.7.3, GS108Tv3 before 7.0.6.3, GS110TPPv1 before 7.0.6.3, GS110TPv3 before 7.0.6.3, GS110TUPv1 before 1.0.4.3, GS710TUPv1 before 1.0.4.3, GS716TP before 1.0.2.3, GS716TPP before 1.0.2.3, GS724TPPv1 before 2.0.4.3, GS724TPv2 before 2.0.4.3, GS728TPPv2 before 6.0.6.3, GS728TPv2 before 6.0.6.3, GS752TPPv1 before 6.0.6.3, GS752TPv2 before 6.0.6.3, MS510TXM before 1.0.2.3, and MS510TXUP before 1.0.2.3.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.