9.8
Out-of-bounds Read
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.

Remedy

PTC has released the following resolutions: Update the impacted product to the latest version: ·         ThingWorx Edge C-SDK: 3.0.0 or later. ·         ThingWorx Edge MicroServer (EMS): v5.4.11 or later. ·         .NET-SDK: v5.8.5 or later. For Kepware products, the vulnerability is mitigated if the ThingWorx Interface is not enabled. To use the ThingWorx Interface without the vulnerability, update to the latest version of the product: ·         Kepware KEPServerEX: v6.13 or later. ·         ThingWorx Kepware Server (formerly ThingWorx Industrial Connectivity): v6.13 or later. ·         ThingWorx Kepware Edge: v1.6 or later. The following products should be upgraded as indicated or in accordance with the applicable organization’s recommendations if the ThingWorx Interface is in use: ·         Rockwell Automation KEPServer Enterprise: v6.13 or later. ·         GE Digital Industrial Gateway Server: v7.613 or later. For more information see PTC’s Customer Support Article .
First published (updated )
Severity
9.8
Integer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.

1 / 2
Source: MITRE

Remedy

PTC has released the following resolutions: Update the impacted product to the latest version: ·         ThingWorx Edge C-SDK: 3.0.0 or later. ·         ThingWorx Edge MicroServer (EMS): v5.4.11 or later. ·         .NET-SDK: v5.8.5 or later. For Kepware products, the vulnerability is mitigated if the ThingWorx Interface is not enabled. To use the ThingWorx Interface without the vulnerability, update to the latest version of the product: ·         Kepware KEPServerEX: v6.13 or later. ·         ThingWorx Kepware Server (formerly ThingWorx Industrial Connectivity): v6.13 or later. ·         ThingWorx Kepware Edge: v1.6 or later. The following products should be upgraded as indicated or in accordance with the applicable organization’s recommendations if the ThingWorx Interface is in use: ·         Rockwell Automation KEPServer Enterprise: v6.13 or later. ·         GE Digital Industrial Gateway Server: v7.613 or later. For more information see PTC’s Customer Support Article .
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203