7.5
AV:N/AC:L/Au:N/C:P/I:P/A:P

Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler.

First published (updated )
Severity
7
CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.

First published (updated )
Severity
5.5
XEE
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.

Remedy

Rockwell Automation encourages users to update to the available software revisions below: Connected Component Workbench: Update to v13.00 ISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned. Safety Instrumented Systems Workstation: Update to v1.2
First published (updated )
Severity
8.6
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited

First published (updated )
Severity
8.6
Path Traversal
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H

The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.

Remedy

Rockwell Automation recommends users of the affected software update to an available software revision (Connected Components Workbench v13.00.00 or later) that addresses the associated risk.
First published (updated )
Severity
8.6
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.

Remedy

Rockwell Automation recommends users of the affected software update to an available software revision (Connected Components Workbench v13.00.00 or later) that addresses the associated risk.
First published (updated )
Severity
8.2
Path Traversal, Input Validation
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file during extraction. This type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.

Remedy

Rockwell Automation recommends users of the affected software update to an available software revision (Connected Components Workbench v13.00.00 or later) that addresses the associated risk.
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.