Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.
Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.
A command injection vulnerability exists in Tenda AC18 V15.03.05.05multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.
A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the ssid parameter of formfastsettingwifiset function.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speeddir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo.