Where
AND
AND
-Infinity
0
Severity
8.6
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L

Tenda AC8V4 V16.03.34.06 was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.

First published (updated )
Severity
7.5
EPSS
0.05%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the getparentControllistInfo function.

First published (updated )
Severity
8.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.

First published (updated )
Severity
7.5
Null Pointer Dereference
AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

First published (updated )
Severity
7.5
EPSS
0.05%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.

First published (updated )
Severity
7.5
EPSS
0.05%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the setqosMiblist function.

First published (updated )
Severity
7.5
EPSS
0.05%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the savevirtualserdata function.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.