Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the setqosMiblist function.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the savevirtualserdata function.
Tenda AC8V4 V16.03.34.06 was discovered to contain stack overflow at /goform/fastsettingwifiset. The manipulation of the argument timeZone leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument timeZone and timeType leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument mac leads to heap-based buffer overflow.
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub47D878.
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the getparentControllistInfo function.
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub47D878 function.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function getparentControllistInfo.
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapskcrypto leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub49E098 function.
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the getparentControllistInfo function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the getparentControllistInfo function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub4a79ec function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function.
A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.