Where
AND
-Infinity
0
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.

First published (updated )
Severity
9.8
EPSS
0.15%
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speeddir parameter in the formSetSpeedWan function.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.

First published (updated )
Severity
8.3
Buffer Overflow
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A weakness has been identified in Tenda AC9 15.03.06.42multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203