Where
AND
-Infinity
0
Severity
8.8
EPSS
0.04%
Buffer Overflow
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42multi allows a remote attacker to execute arbitrary code via the addwhitenode function.

First published (updated )
Severity
8
EPSS
0.04%
Buffer Overflow
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function.

First published (updated )
Severity
8.8
EPSS
0.04%
Buffer Overflow
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function.

First published (updated )
Severity
8.8
EPSS
0.04%
Buffer Overflow
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function.

First published (updated )
Severity
9.8
EPSS
0.04%
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function.

First published (updated )
Severity
8.3
Buffer Overflow
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security vulnerability has been detected in Tenda AC9 15.03.06.42multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.starttime/sys.schedulereboot.endtime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42multi were discovered to contain a stack overflow via parameter ssid at url /goform/fastsettingwifiset.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203