Where
-Infinity
0
Severity
4.3
EPSS
0.04%
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

TOTOLINK N300RT V2.1.8-B20201030.1539 contains a Store Cross-site scripting (XSS) vulnerability in MAC Filtering under the Firewall Page.

First published (updated )
Severity
5.5
EPSS
0.04%
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L

TOTOLINK N300RT V2.1.8-B20201030.1539 contains a Store Cross-site scripting (XSS) vulnerability in Port Forwarding under the Firewall Page.

First published (updated )
Severity
6.5
EPSS
0.04%
XSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L

TOTOLINK N300RT V2.1.8-B20201030.1539 contains a Store Cross-site scripting (XSS) vulnerability in IP/Port Filtering under the Firewall Page.

First published (updated )
Severity
5.4
EPSS
0.04%
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N

TOTOLINK N300RT V2.1.8-B20201030.1539 contains a Store Cross-site scripting (XSS) vulnerability in Access Control under the Wireless Page.

First published (updated )
Severity
6.1
EPSS
0.04%
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

TOTOLINK N300RT V2.1.8-B20201030.1539 contains a Store Cross-site scripting (XSS) vulnerability in WDS Settings under the Wireless Page.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

TOTOLINK N300RT version 3.2.4-B20180730.0906 has a post-authentication RCE due to incorrect access control, allows attackers can bypass front-end security restrictions and execute arbitrary code.

First published (updated )
Severity
9
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.