Where
AND
-Infinity
0
Severity
9.1
EPSS
0.01%
Race Condition
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Impact

A remote client may send a request that is exactly recvbytes (defaults to 8192) long, followed by a secondary request using HTTP pipelining.

When request lookahead is disabled (default) we won't read any more requests, and when the first request fails due to a parsing error, we simply close the connection.

However when request lookahead is enabled, it is possible to process and receive the first request, start sending the error message back to the client while we read the next request and queue it. This will allow the secondary request to be serviced by the worker thread while the connection should be closed.

Patches

Waitress 3.0.1 fixes the race condition.

Workarounds

Disable channelrequestlookahead, this is set to 0 by default disabling this feature. For this vulnerability this value is required to be changed from the default.

For more information

If you have any questions or comments about this advisory: Open an issue in https://github.com/Pylons/waitress/issues (if not sensitive or security related) email the Pylons Security mailing list: pylons-project-security@googlegroups.com (if security related)

Thanks

- m4yfly and urn1ce From TianGong Team of Legendsec at Qi'anxin Group.

1 / 3
Source: GitHub
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203