-Infinity
0
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.

First published (updated )
Severity
10
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded 'donglebridge' program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user 'nobody'.

First published (updated )
Severity
10
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.

First published (updated )
Severity
9.8
Command Injection, OS Command Injection, XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the filetransfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

1 / 2
First published (updated )
Severity
9.8
Infoleak
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image.

First published (updated )
Severity
9.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco TransForm NDN-210 Lite, NDN-210 Pro, NDN-211 Lite, and NDN-211 Pro before 3.8 allows Command Injection (issue 1 of 4). The NDN-210 has a web administration panel which is made available over https. The logon method is basic authentication. There is a command injection issue that will result in unauthenticated remote code execution in the username and password fields of the logon prompt. The NDN-210 is part of Barco TransForm N solution and includes the patch from TransForm N version 3.8 onwards.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco wePresent WiPG-1600W devices download code without an Integrity Check. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W firmware does not perform verification of digitally signed firmware updates and is susceptible to processing and installing modified/malicious images.

First published (updated )
Severity
9.8
Infoleak
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco wePresent WiPG-1600W devices allow Authentication Bypass. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W web interface does not use session cookies for tracking authenticated sessions. Instead, the web interface uses a "SEID" token that is appended to the end of URLs in GET requests. Thus the "SEID" would be exposed in web proxy logs and browser history. An attacker that is able to capture the "SEID" and originate requests from the same IP address (via a NAT device or web proxy) would be able to access the user interface of the device without having to know the credentials.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate's Chain of Trust. The embedded 'donglebridge' program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain.

First published (updated )
Severity
9
OS Command Injection, Command Injection
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device.

First published (updated )
Severity
8.8
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Barco MirrorOp Windows Sender before 2.5.3.65 uses cleartext HTTP and thus allows rogue software upgrades. An attacker on the local network can achieve remote code execution on any computer that tries to update Windows Sender due to the fact that the upgrade mechanism is not secured (is not protected with TLS).

First published (updated )
Severity
8.1
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed 'ClickshareForWindows.exe' binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

An issue was discovered in Barco MirrorOp Windows Sender before 2.5.4.70. An attacker in the local network is able to achieve Remote Code Execution (with user privileges of the local user) on any device that tries to connect to a WePresent presentation system.

First published (updated )
Severity
7.8
Input Validation
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

An issue was discovered on Barco ClickShare CSE-200 and CS-100 Base Units with firmware before 1.6.0.3. Sending an arbitrary unexpected string to TCP port 7100 respecting a certain frequency timing disconnects all clients and results in a crash of the Unit.

First published (updated )
Severity
7.6
Command Injection
AC:L/AV:P/A:H/C:H/I:H/PR:N/S:C/UI:N

An injection vulnerability in Barco ClickShare CX-30/20, C-5/10, and ClickShare Bar Pro and Core models, running firmware before 2.21.1, allows physically proximate attackers or local admins to the webUI to trigger OS-level command execution as root.

First published (updated )
Severity
7.5
Path Traversal
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Barco ClickShare Huddle CS-100 devices before 1.9.0 and CSE-200 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Base Unit implements encryption at rest using encryption keys which are shared across all ClickShare Base Units of models CS-100 & CSE-200.

First published (updated )
Severity
7.5
Path Traversal
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Barco Control Room Management through Suite 2.9 Build 0275 was discovered to be vulnerable to directory traversal, allowing attackers to access sensitive information and components. Requests must begin with the "GET /..\.." substring.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication.

First published (updated )
Severity
7.2
Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Barco TransForm N before 3.8 allows Command Injection (issue 2 of 4). The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users of the administration panel to perform authenticated remote code execution. An issue exists in splitcardcmd.php in which the http parameters xmodules, ymodules and savelocking are not properly handled. The NDN-210 is part of Barco TransForm N solution and includes the patch from TransForm N version 3.8 onwards.

First published (updated )
Severity
7.2
Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users to the administration panel to perform authenticated remote code execution. An issue exists in ngpsystemcmd.php in which the http parameters "xmodules" and "ymodules" are not properly handled. The NDN-210 is part of Barco TransForm N solution and this vulnerability is patched from TransForm N version 3.8 onwards.

First published (updated )
Severity
7.2
Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users to the administration panel to perform authenticated remote code execution. An issue exists in splitcardcmd.php in which the http parameter "locking" is not properly handled. The NDN-210 is part of Barco TransForm N solution and this vulnerability is patched from TransForm N version 3.8 onwards.

First published (updated )
Severity
7.2
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password.

First published (updated )
Severity
6.9
CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used.

First published (updated )
Severity
6.5
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Barco wePresent WiPG-1600W devices have Unprotected Transport of Credentials. Affected Version(s): 2.5.1.8. An attacker armed with hardcoded API credentials (retrieved by exploiting CVE-2020-28329) can issue an authenticated query to display the admin password for the main web user interface listening on port 443/tcp of a Barco wePresent WiPG-1600W device.

First published (updated )
Severity
6.1
XSS
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203