Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.
The web server is vulnerable to reflected XSS and therefore an attacker might be able to execute scripts on a client’s computer by sending the client a manipulated URL.
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
Deserialization of Untrusted Data in the BVMS Mobile Video Service (BVMS MVS) allows an unauthenticated remote attacker to execute arbitrary code on the system. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.0.329 and 7.5 and older. This affects Bosch DIVAR IP 3000 and DIVAR IP 7000 if a vulnerable BVMS version is installed.
An issue was discovered in several Bosch IP cameras for firmware versions 6.32 and higher. A malicious client could potentially succeed in the unauthorized execution of code on the device via the network interface.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands.
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 runs its web server with root privilege. In combination with CVE-2022-23534 this could give an attacker root access to the switch.
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
The vulnerability allows an unauthenticated remote attacker to upload arbitrary files under the context of the application OS user (“root”) via a crafted HTTP request.
The vulnerability allows a remote attacker to authenticate to the web application with high privileges through multiple hidden hard-coded accounts.
The vulnerability allows a remote attacker to authenticate to the SSH service with root privileges through a hidden hard-coded account.
The vulnerability allows an unauthenticated remote attacker to perform a Denial-of-Service (DoS) attack or, possibly, obtain Remote Code Execution (RCE) via a crafted network request.
The vulnerability allows an unauthenticated remote attacker to perform a Denial-of-Service (DoS) attack or, possibly, obtain Remote Code Execution (RCE) via a crafted network request.
The vulnerability allows an unauthenticated remote attacker to perform a Denial-of-Service (DoS) attack or, possibly, obtain Remote Code Execution (RCE) via a crafted network request.
The vulnerability allows an unauthenticated remote attacker to perform a Denial-of-Service (DoS) attack or, possibly, obtain Remote Code Execution (RCE) via a crafted network request.
The vulnerability allows an unauthenticated remote attacker to perform a Denial-of-Service (DoS) attack or, possibly, obtain Remote Code Execution (RCE) via a crafted network request.
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
An issue was discovered in several Bosch Smart Home cameras (360 degree indoor camera and Eyes outdoor camera) with firmware before 6.52.4. A malicious client could potentially succeed in the unauthorized execution of code on the device via the network interface, because there is a buffer overflow in the RCP+ parser of the web server.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
BF-OS version 3.x up to and including 3.83 do not enforce strong passwords which may allow a remote attacker to brute-force the device password.
Improper Access Control in the Kiosk Mode functionality of Bosch Recording Station allows a local unauthenticated attacker to escape from the Kiosk Mode and access the underlying operating system.
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
A directory traversal vulnerability in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location.
A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000).
The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.
The vulnerability allows a remote attacker to upload arbitrary files in all paths of the system under the context of the application OS user (“root”) via a crafted HTTP request. By abusing this vulnerability, it is possible to obtain remote code execution (RCE) with root privileges on the device.