Ruckus vRioT through 1.5.1.0.21 has an API backdoor that is hardcoded into validatetoken.py. An unauthenticated attacker can interact with the service API by using a backdoor value as the Authorization header.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the pppoe function via the pppoeusername, pppoepasswd, and pppoeservicename parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the time and time zone function via the hprimaryntpserver, hbackupntpserver, and htimezone parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the upnp function via the upnpttl parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 were discovered to contain a command injection vulnerability in the dhcp function via the hostname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 were discovered to contain a command injection vulnerability in the ddns function via the ddnsname, ddnspwd, hddns、ddnshost parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the pptp (wanpptp.html) function via the pptpfixip, pptpfixmask, pptpfixgw, and wandns1stat parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the wps setting function via the wpsenroleepin parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Arris TR3300 v1.0.13 was discovered to contain a command injection vulnerability in the static ip settings function via the wanipstat, wanmaskstat, wangwstat, and wandns1stat parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
In RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build, OS command injection can occur via an IP address field provided by an authenticated user.
An arbitrary code execution vulnerability exists in Arris SURFboard SGB6950AC2 devices. An unauthenticated attacker can exploit this vulnerability to achieve code execution as root.
Ruckus Wireless Admin through 10.4 allows Remote Code Execution via an unauthenticated HTTP GET Request, as demonstrated by a /forms/doLogin?loginusername=admin&password=password$(curl substring.
RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build has a hardcoded SSH private key for a root-equivalent user account.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where a path-traversal flaw in the web interface lets the server execute attacker-supplied EJS templates outside permitted directories, allowing a remote unauthenticated attacker who can upload a template (e.g., via FTP) to escalate privileges and run arbitrary template code on the controller.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the functions stamgrcfgadptaddStaFavourite and stamgrcfgadptaddStaIot pass a client hostname directly to snprintf as the format string. A remote attacker can exploit this flaw either by sending a crafted request to the authenticated endpoint /admin/conf.jsp, or without authentication and without direct network access to the controller by spoofing the MAC address of a favourite station and embedding malicious format specifiers in the DHCP hostname field, resulting in unauthenticated format-string processing and arbitrary code execution on the controller.
In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessible over the network on TCP port 5432. An attacker can use the hardcoded credentials to authenticate remotely, gaining superuser access to the database. This allows creation of administrative users for the web interface, extraction of password hashes, and execution of arbitrary OS commands.
In RUCKUS Network Director (RND) < 4.5.0.56, the OVA appliance contains hardcoded SSH keys for the postgres user. These keys are identical across all deployments, allowing an attacker with network access to authenticate via SSH without a password. Once authenticated, the attacker can access the PostgreSQL database with superuser privileges, create administrative users for the web interface, and potentially escalate privileges further.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. An Undocumented Backdoor exists, allowing shell access via a developer account.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints.
ARRIS SBG6580-2 D30GW-SEAEAGLE-1.5.2.5-GA-00-NOSH devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
ARRIS DG950A 7.10.145 and DG950S 7.10.145.EURO devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC39412.5s3PRODsey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG16822.2p7s2PRODsey) devices allows remote attackers to execute arbitrary code via a specific (but unstated) exposed service. NOTE: the scope of this CVE does NOT include the concept of "Unnecessary Services" in general; the scope is only a single service that is unnecessarily exposed, leading to remote code execution. The details of that service might be disclosed at a later date.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.
CommScope ARRIS TR4400 devices with firmware through A1.00.004-180301 are vulnerable to an authentication bypass to the administrative interface because they include the current base64 encoded password within http://192.168.1.1/login.html. Any user connected to the Wi-Fi can exploit this.
CommScope ARRIS TR4400 devices with firmware through A1.00.004-180301 are vulnerable to an authentication bypass to the administrative interface because they include the current base64 encoded password within http://192.168.1.1/basicsett.html. Any user connected to the Wi-Fi can exploit this.
A vulnerability in the web-based interface of the RUCKUS Cloudpath product on version 5.12 build 5538 or before to could allow a remote, unauthenticated attacker to execute persistent XSS and CSRF attacks against a user of the admin management interface. A successful attack, combined with a certain admin activity, could allow the attacker to gain full admin privileges on the exploited system.
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver https service with the tech account and an empty password, which allows remote attackers to obtain root privileges by establishing a session on port 49955 and then installing new software, such as BusyBox with "nc -l" support.
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures ssh-permanent-enable WAN SSH logins to the remotessh account with the 5SaP9I26 password, which allows remote attackers to access a "Terminal shell v1.0" service, and subsequently obtain unrestricted root privileges, by establishing an SSH session and then entering certain shell metacharacters and BusyBox commands.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where a hidden debug script .apdebug.sh invoked from the restricted CLI does not properly sanitize its input, allowing an authenticated attacker to execute arbitrary commands as root on the controller or specified target.