See how crestron compares to other vendors in security performance
A hidden console command is vulnerable to command injection flaw when control characters are passed to its second argument.
A third party researcher Eugene Lim had discovered vulnerability in the way console command passes to a popen function call. Attackers with authenticated access to SSH console of Crestron devices may use to run underlying OS commands.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.This issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.001.0031.001.
Confirmed Affected Hardware: TSW-760, TSW-1060
Confirmed Affected Firmware: 3.002.1061 - (no fix released, product discontinued)
For x70
The Affected Firmware:- 3.000.0110.001 and versions below
The Fixed Firmware:- 3.001.0031.001
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.This issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.001.0034.001.
A specially crafted SCP command sent via SSH login string can lead a valid administrator user to gain Privileged Operating System access on the device.
Following Products Models are affected:
TSW-x70 TSW-x60 TST-1080 AM-3000/3100/3200 Soundbar VB70 HD-PS622/621/402 HD-TXU-RXU-4kZ-211 HD-MDNXM-4KZ-E
Note: additional firmware updates will be published once made available
266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
There is no visible indication when the system is recording and recording can be enabled remotely via a network API. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
When Enable Debug Images in Crestron Automate VX is active, snapshots of the captured video or portions thereof are stored locally on the system, and there is no visible indication that this is being done.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.
On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash.
Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell.
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack.
Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt.
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation.
An issue was discovered on Crestron HD-MD4X2-4K-E 1.0.0.2159 devices. When the administrative web interface of the HDMI switcher is accessed unauthenticated, user credentials are disclosed that are valid to authenticate to the web interface. Specifically, aj.html sends a JSON document with uname and upassword fields.
On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request.
Crestron DMC-STRO 1.0 devices allow remote command execution as root via shell metacharacters to the ping function.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uartbridge.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the filetransfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.