Where
AND
-Infinity
0
Severity
9.8
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

D-Link DIR-820L 1.05B03 was discovered to contain remote command execution (RCE) vulnerability via HTTP POST to get set ccp.

1 / 2
First published (updated )
Severity
7.2
EPSS
0.24%
Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/setprohibiting via the corresponding function, triggering remote command execution.

1 / 2
Source: NVD
First published (updated )
Severity
9.8
EPSS
1.27%
Command Injection
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

UNSUPPORTED WHEN ASSIGNED A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nassharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

1 / 2
Source: MITRE
First published (updated )
Severity
9.8
EPSS
83.36%
Command Injection
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L

UNSUPPORTED WHEN ASSIGNED A vulnerability, which was classified as critical, was found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. Affected is an unknown function of the file /cgi-bin/nassharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument system leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-259284. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

1 / 2
Source: MITRE
First published (updated )
Severity
9.8
EPSS
0.16%
Path Traversal
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in D-Link DIR-859 1.06B01. It has been rated as critical. Affected by this issue is some unknown functionality of the file /hedwig.cgi of the component HTTP POST Request Handler. The manipulation of the argument service with the input ../../../../htdocs/webinc/getcfg/DHCPS6.BRIDGE-1.xml leads to path traversal. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-251666 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

1 / 2
Source: MITRE
First published (updated )
Severity
9.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

D-Link DIR-820 routers contain an OS command injection vulnerability that allows a remote, unauthenticated attacker to escalate privileges to root via a crafted payload with the pingaddr parameter to ping.ccp.

1 / 2
Source: CISA
First published (updated )
Severity
8.8
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

D-Link DNR-322L contains a download of code without integrity check vulnerability that could allow an authenticated attacker to execute OS level commands on the device. The impacted products could be end-of-life (EoL) and/or end-of-service (EoS). Users should discontinue product utilization.

1 / 2
Source: CISA
First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

D-Link Go-RT-AC750 GORTAC750revAv101b03 and GO-RT-AC750revBFWv200b02 are vulnerable to Buffer Overflow via cgibin, hnapmain,

1 / 2
First published (updated )
Severity
9.8
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A remote code execution vulnerability exists in all series H/W revisions routers via the DDNS function in ncc2 binary file.

1 / 2
Source: CISA
First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

An informtion disclosure issue exists in D-LINK-DIR-605 B2 Firmware Version : 2.01MT. An attacker can obtain a user name and password by forging a post request to the / getcfg.php page

1 / 2
First published (updated )
Severity
8.8
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

UNSUPPORTED WHEN ASSIGNED D-Link DIR-610 devices allow Remote Command Execution via the cmd parameter to command.php. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

1 / 3
First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An issue was discovered on D-Link DIR-825 R1 devices through 3.0.1 before 2020-11-20. A buffer overflow in the web interface allows attackers to achieve pre-authentication remote code execution.

1 / 2
First published (updated )
Severity
9.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

D-Link DNS-320 FW v2.06B01 Revision Ax is affected by command injection in the systemmgr.cgi component, which can lead to remote arbitrary code execution.

1 / 2
First published (updated )
Severity
8.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. cgi-bin/ddnsenc.cgi allows authenticated command injection.

1 / 2
First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. The unauthenticated /config/getuser endpoint allows for remote administrator password disclosure.

1 / 2
First published (updated )
Severity
7.8
Command Injection, OS Command Injection
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

D-Link DWL-2600AP 4.2.0.15 Rev A devices have an authenticated OS command injection vulnerability via the Save Configuration functionality in the Web interface, using shell metacharacters in the admin.cgi?action=configsave configBackup or downloadServerip parameter.

1 / 2
First published (updated )
Severity
9.8
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The UPnP endpoint URL /gena.cgi in the D-Link DIR-859 Wi-Fi router 1.05 and 1.06B01 Beta01 allows an Unauthenticated remote attacker to execute system commands as root, by sending a specially crafted HTTP SUBSCRIBE request to the UPnP service when connecting to the local network.

1 / 2
First published (updated )
Severity
9.8
Command Injection, OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a "PingTest" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825.

1 / 2
First published (updated )
Severity
9.8
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The loginmgr.cgi script in D-Link DNS-320 through 2.05.B10 is vulnerable to remote command injection.

1 / 2
First published (updated )
Severity
9.8
Command Injection, OS Command Injection
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Multiple D-Link routers contain an unspecified vulnerability that allows for execution of OS commands.

1 / 2
Source: CISA
First published (updated )
Severity
9.8
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

D-Link DSL-2750B devices before 1.05 allow remote unauthenticated command injection via the login.cgi cli parameter, as exploited in the wild in 2016 through 2022.

1 / 2
Source: NVD
First published (updated )
Severity
7.2
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

setSystemCommand on D-Link DCS-930L devices before 2.12 allows a remote attacker to execute code via an OS command in the SystemCommand parameter.

1 / 2
First published (updated )
Severity
8.8
Command Injection
AV:N/AC:L/Au:N/C:C/I:C/A:C

The D-Link DIR-645 Wired/Wireless Router Rev. Ax with firmware 1.04b12 and earlier allows remote attackers to execute arbitrary commands via a GetDeviceSettings action to the HNAP interface.

1 / 2
First published (updated )
Severity
9.8
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The ping tool in multiple D-Link and TRENDnet devices allow remote attackers to execute arbitrary code via the pingaddr parameter to ping.ccp.

1 / 2
First published (updated )
Severity
8.8
CSRF
AV:N/AC:M/Au:N/C:P/I:P/A:P

D-Link DIR-600 routers contain a cross-site request forgery (CSRF) vulnerability that allows an attacker to change router configurations by hijacking an existing administrator session.

1 / 2
Source: CISA
First published (updated )
Severity
5.4
XSS
AV:N/AC:M/Au:S/C:N/I:P/A:N

Multiple cross-site scripting (XSS) vulnerabilities in D-Link DSL-2760U Gateway (Rev. E1) allow remote authenticated users to inject arbitrary web script or HTML via the (1) ntpServer1 parameter to sntpcfg.cgi, username parameter to (2) ddnsmngr.cmd or (3) todmngr.tod, (4) TodUrlAdd parameter to urlfilter.cmd, (5) appName parameter to scprttrg.cmd, (6) fltName in an add action or (7) rmLst parameter in a remove action to scoutflt.cmd, (8) groupName parameter to portmapcfg.cmd, (9) snmpRoCommunity parameter to snmpconfig.cgi, (10) fltName parameter to scinflt.cmd, (11) PolicyName in an add action or (12) rmLst parameter in a remove action to prmngr.cmd, (13) ippName parameter to ippcfg.cmd, (14) smbNetBiosName or (15) smbDirName parameter to samba.cgi, or (16) wlSsid parameter to wlcfg.wl.

1 / 2
First published (updated )
Severity
5.7
AV:N/AC:L/Au:S/C:C/I:N/A:N

The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors.

1 / 2
First published (updated )
Severity
9.8
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security flaw has been discovered in D-Link DIR-825 up to 2.10. Affected by this vulnerability is the function sub4106d4 of the file apply.cgi. The manipulation of the argument countdowntime results in buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be exploited. This vulnerability only affects products that are no longer supported by the maintainer.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.