Where
-Infinity
0

Vendor Risk Score

See how delta industrial automation compares to other vendors in security performance

View Risk Score →
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Delta Industrial Automation CNCSoft ScreenEditor Versions 1.01.28 (with ScreenEditor Version 1.01.2) and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.

First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Delta Industrial Automation COMMGR Versions 1.12 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code.

First published (updated )
Severity
9.3
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Electronics DOPSoft Version 4.0.8.21 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.

1 / 5
First published (updated )
Severity
9.3
Null Pointer Dereference
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Electronics DOPSoft Version 4.0.8.21 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.

1 / 2
First published (updated )
Severity
8.1
Path Traversal
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Remedy

Delta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation TPEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TPE files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation TPEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TPE files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-20-961
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.

1 / 3
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-940
Severity
7.8
Buffer Overflow
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.

1 / 3
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. An uninitialized pointer may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.

1 / 2
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-20-948
Severity
7.8
Buffer Overflow
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

A stack-based buffer overflow vulnerability in Delta Electronics DOPSoft Version 4.00.11 and prior may be exploited by processing a specially crafted project file, which may allow an attacker to execute arbitrary code.

1 / 2
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-21-509
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CNCSoft-B Versions 1.0.0.3 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

1 / 2
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-21-524
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPB files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Electronics' CNCSoft ScreenEditor in versions prior to v1.01.30 could allow the corruption of data, a denial-of-service condition, or code execution. The vulnerability may allow an attacker to remotely execute arbitrary code.

1 / 2
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-21-444
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CNCSoft-B Versions 1.0.0.3 and prior is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.

1 / 2
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-21-445
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B DOPSoft. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of DPB files. When parsing the wMessageLen element, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the Administrator.

Advisory
ZDI-19-401
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Delta Industrial Automation CNCSoft ScreenEditor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of DPB files. When parsing the wMessageLen element, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the Administrator.

Severity
7.8
Buffer Overflow, Input Validation
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack.

1 / 6
First published (updated )
Severity
7.8
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation CNCSoft-B. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DPA files by the DOPSoft program. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process.

Advisory
ZDI-21-045

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.