Software

emerson deltav
15
emerson x-stream enhanced xefd
9
emerson x-stream enhanced xegk firmware
9
emerson x-stream enhanced xegp
9
emerson x-stream enhanced xexf firmware
9
emerson deltav distributed control system
8
emerson wireless 1420 gateway firmware
8
emerson wirelesshart 1410 gateway
8
emerson proficy machine edition
7
emerson wireless 1410 gateway
7
emerson wireless 1410 gateway firmware
7
emerson wireless 1410d gateway
7
emerson wirelesshart 1420 gateway
7
emerson x-stream enhanced xegk
7
emerson x-stream enhanced xexf
7
emerson deltav workstation
6
emerson openenterprise
6
emerson deltav distributed control system sq controller firmware
5
emerson deltav distributed control system sx controller firmware
5
emerson deltav proessentials scientific graph
5
emerson dl 8000 remote terminal unit firmware
5
emerson electric's proficy
5
emerson roc 800l remote terminal unit
5
emerson se4002s1t2b6 high side 40-pin mass i/o terminal block
5
emerson se4002s1t2b6 high side 40-pin mass i/o terminal block firmware
5
emerson se4003s2b4 16-pin mass i/o terminal block
5
emerson se4003s2b4 16-pin mass i/o terminal block firmware
5
emerson se4003s2b524-pin mass i/o terminal block
5
emerson se4003s2b524-pin mass i/o terminal block firmware
5
emerson se4017p0 h1 i/o interface card and terminal block
5
emerson se4017p0 h1 i/o interface card and terminl block firmware
5
emerson se4017p1 h1 i/o card with integrated power
5
emerson se4017p1 h1 i/o card with integrated power firmware
5
emerson se4019p0 simplex h1 4-port plus fieldbus i/o interface with terminalblock
5
emerson se4019p0 simplex h1 4-port plus fieldbus i/o interface with terminalblock firmware
5
emerson se4026 virtual i/o module 2
5
emerson se4026 virtual i/o module 2 firmware
5
emerson se4027 virtual i/o module 2
5
emerson se4027 virtual i/o module 2 firmware
5
emerson se4032s1t2b8 high side 40-pin do mass i/o terminal block
5
emerson se4032s1t2b8 high side 40-pin do mass i/o terminal block firmware
5
emerson se4037p0 h1 i/o interface card and terminal block
5
emerson se4037p0 h1 i/o interface card and terminal block firmware
5
emerson se4037p1 redundant h1 i/o card with integrated power and terminal block
5
emerson se4037p1 redundant h1 i/o card with integrated power and terminal block firmware
5
emerson se4039p0 redundant h1 4-port plus fieldbus i/o interface with terminalblock
5
emerson se4039p0 redundant h1 4-port plus fieldbus i/o interface with terminalblock firmware
5
emerson se4052s1t2b6 high side 40-pin mass i/o terminal block
5
emerson se4052s1t2b6 high side 40-pin mass i/o terminal block firmware
5
emerson se4082s1t2b8 high side 40-pin do mass i/o terminal block
5
Severity
8.5
AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Emerson PAC Machine Edition 9.80 contains an unquoted service path vulnerability in the TrapiServer service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in the service configuration to inject malicious code that would execute with LocalSystem permissions during service startup.

First published (updated )

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Emerson Movicon. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-3871.

First published (updated )

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Emerson Movicon. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-3871.

First published (updated )
Advisory
ZDI-25-1037
Severity
5.9
Input Validation
AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N

Emerson ValveLink products receive input or data, but does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.

Remedy

Emerson recommends users update their Valvelink software to ValveLink 14.0 or later. The upgrade can be downloaded from the Emerson website https://www.emerson.com/en-us/support/software-downloads-drivers  .For more information see the associated Emerson security notification. https://www.emerson.com/en-us/support/security-notifications
First published (updated )
Severity
5.9
AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

Emerson ValveLink products use a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.

Remedy

Emerson recommends users update their Valvelink software to ValveLink 14.0 or later. The upgrade can be downloaded from the Emerson website https://www.emerson.com/en-us/support/software-downloads-drivers  .For more information see the associated Emerson security notification. https://www.emerson.com/en-us/support/security-notifications
First published (updated )
Severity
8.5
AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Emerson ValveLink products do not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.

Remedy

Emerson recommends users update their Valvelink software to ValveLink 14.0 or later. The upgrade can be downloaded from the Emerson website https://www.emerson.com/en-us/support/software-downloads-drivers  .For more information see the associated Emerson security notification. https://www.emerson.com/en-us/support/security-notifications
First published (updated )
Severity
8.5
AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Emerson ValveLink Products store sensitive information in cleartext within a resource that might be accessible to another control sphere.

Remedy

Emerson recommends users update their Valvelink software to ValveLink 14.0 or later. The upgrade can be downloaded from the Emerson website https://www.emerson.com/en-us/support/software-downloads-drivers  .For more information see the associated Emerson security notification. https://www.emerson.com/en-us/support/security-notifications
First published (updated )
Severity
9.4
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L

Emerson ValveLink Products store sensitive information in cleartext in memory. The sensitive memory might be saved to disk, stored in a core dump, or remain uncleared if the product crashes, or if the programmer does not properly clear the memory before freeing it.

Remedy

Emerson recommends users update their Valvelink software to ValveLink 14.0 or later. The upgrade can be downloaded from the Emerson website https://www.emerson.com/en-us/support/software-downloads-drivers  .For more information see the associated Emerson security notification. https://www.emerson.com/en-us/support/security-notifications
First published (updated )
Severity
7.8
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Incorrect directory permissions for the shared NI RabbitMQ service may allow a local authenticated user to read RabbitMQ configuration information and potentially enable escalation of privileges.

First published (updated )
Severity
7.8
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Incorrect permissions in the installation directories for shared SystemLink Elixir based services may allow an authenticated user to potentially enable escalation of privilege via local access.

First published (updated )
Severity
9.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

In Emerson Rosemount GC370XA, GC700XA, and GC1500XA products, an unauthenticated user with network access could obtain access to sensitive information or cause a denial-of-service condition.

Remedy

Emerson recommends end users update the affected products' firmware. For update information, contact Emerson Security https://www.emerson.com/en-us/support/security-notifications  web page.
First published (updated )
Severity
9.8
Command Injection
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

In Emerson Rosemount GC370XA, GC700XA, and GC1500XA products, an unauthenticated user with network access could execute arbitrary commands in root context from a remote computer.

Remedy

Emerson recommends end users update the affected products' firmware. For update information, contact Emerson Security https://www.emerson.com/en-us/support/security-notifications  web page.
First published (updated )
Severity
9.8
Command Injection
AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:H

In Emerson Rosemount GC370XA, GC700XA, and GC1500XA products, an authenticated user with network access could run arbitrary commands from a remote computer.

Remedy

Emerson recommends end users update the affected products' firmware. For update information, contact Emerson Security https://www.emerson.com/en-us/support/security-notifications  web page.
First published (updated )
Severity
8.3
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

In Emerson Rosemount GC370XA, GC700XA, and GC1500XA products, an unauthenticated user with network access could bypass authentication and acquire admin capabilities.

Remedy

Emerson recommends end users update the affected products' firmware. For update information, contact Emerson Security https://www.emerson.com/en-us/support/security-notifications  web page.
First published (updated )
Severity
9.4
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H

ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Emerson DeltaV Distributed Control System (DCS) has insufficient verification of firmware integrity (an inadequate checksum approach, and no signature). This affects versions before 14.3 of DeltaV M-series, DeltaV S-series, DeltaV P-series, DeltaV SIS, and DeltaV CIOC/EIOC/WIOC IO cards.

First published (updated )
Severity
7.8
Malicious File Upload
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-353 Missing Support for Integrity Check, and has no authentication or authorization of data packets after establishing a connection for the SRTP protocol.

First published (updated )
Severity
5.5
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N

Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-345 Insufficient Verification of Data Authenticity, and can display logic that is different than the compiled logic.

First published (updated )
Severity
5.9
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N

Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-347 Improper Verification of Cryptographic Signature, and does not properly verify compiled logic (PDT files) and data blocks data (BLD/BLK files).

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-284 Improper Access Control, and stores project data in a directory with improper access control lists.

First published (updated )
Severity
7.3
Path Traversal
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '\..\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering station onto Windows in a way that executes the malicious code.

First published (updated )
Severity
9.1
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

The Emerson ControlWave 'Next Generation' RTUs through 2022-05-02 mishandle firmware integrity. They utilize the BSAP-IP protocol to transmit firmware updates. Firmware updates are supplied as CAB archive files containing a binary firmware image. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.

First published (updated )
Severity
9.6
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Emerson OpenBSI through 2022-04-29 mishandles credential storage. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. This environment provides access control functionality through user authentication and privilege management. The credentials for various users are stored insecurely in the SecUsers.ini file by using a simple string transformation rather than a cryptographic mechanism.

First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

First published (updated )
Severity
8.1
Weak Encryption
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities.

First published (updated )
Severity
5.5
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.

First published (updated )
Severity
5.5
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350.

First published (updated )
Severity
5.5
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203