Where
-Infinity
0
Severity
6.5
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

A flaw in the authorization mechanism for Media Gateway API in Genetec Security Center may allow a user with no playback privileges to generate video thumbnails.

First published (updated )
Severity
7.5
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

A flaw in the authentication mechanism for video stream requests in Genetec Security Center 5.14.0.0 prior to build 5.14.178.18 may allow an unauthenticated attacker to access live video streams.

First published (updated )
Severity
7.8
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A high security vulnerability affecting Security Center main server installations has been identified. It could allow an attacker with local OS privileges to the main server to access the Server Admin credentials. A third party hired by Genetec found the issue. There is currently no evidence of active exploitation.

This vulnerability is associated with specific installation package builds rather than the product version identifier alone. Certain versions (including 5.10.4.0, 5.11.3.0, 5.12.2.0 and 5.13.3.0) were released with both vulnerable and remediated installation packages under the same version number.

Consequently, version-based comparison alone is insufficient to determine exposure. Only installations performed using vulnerable builds are affected. Remediated builds can be distinguished using verified installation package hashes. For the complete list of fixed build hashes, refer to the security advisory section.

First published (updated )
Severity
7.8
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A high-severity vulnerability in the deployment of Genetec RabbitMQ that allows a privilege escalation attack.

First published (updated )
Severity
5.8
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X

Local privilege escalation in Genetec Update Service. An authenticated, low-privileged, Windows user could exploit this vulnerability to gain elevated privileges on the affected system.

Remedy

This issue is fixed in Genetec Update Service 2.10.600 and all later versions. Internet connected Genetec Update Service will automatically update themselves.
First published (updated )
Severity
5.8
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X

Local admin could to leak information from the Genetec Update Service configuration web page. An authenticated, admin privileged, Windows user could exploit this vulnerability to gain elevated privileges in the Genetec Update Service. Could be combined with CVE-2025-1789 to achieve low privilege escalation.

Remedy

This issue is fixed in Genetec Update Service 2.10.600 and all later versions. Internet connected Genetec Update Service will automatically update themselves.
First published (updated )
Severity
5.8
CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X

Local privilege escalation in Genetec Sipelia Plugin. An authenticated low-privileged Windows user could exploit this vulnerability to gain elevated privileges on the affected system.

Remedy

Hotfix 2.14.271 must be installed on client and server machines to resolve this issue. This issue will also be fixed in all later versions.
First published (updated )
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A critical severity vulnerability has been identified in the ALPR Manager role of Security Center that could allow attackers to gain administrative access to the Genetec Security Center system. The Genetec engineering team discovered this issue internally. There is currently no evidence that this vulnerability has been exploited in the wild.

Remedy

This issue is fixed in Security Center 5.13.2.3, 5.12.2.12, 5.11.3.25, 5.10.4.29, 5.9.5.10 and all later versions. Customers running an affected version of Security Center should apply the latest update as soon as possible. Customers not using AutoVu automatic license plate recognition (ALPR) should deactivate the ALPR Manager role. You can find out how by searching Deactivating and activating roles in the TechDoc Hub.
First published (updated )
Severity
8.8
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

SQL Injection in the Hardware Inventory report of Security Center 5.11.2.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203