See how grandstream compares to other vendors in security performance
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
Grandstream GXV3501, GXV3504, GXV3601, GXV3601HD/LL, GXV3611HD/LL, GXV3615W/P, GXV3651FHD, GXV3662HD, GXV3615WPHD, GXV3500, and possibly other camera models with firmware 1.0.4.11, have a hardcoded account "!#/" with the same password, which makes it easier for remote attackers to obtain access via a TELNET session.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via SSH. An authenticated remote attacker can execute commands as the root user by issuing a specially crafted "unset" command.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can bypass command injection mitigations and execute commands as the root user by sending a crafted HTTP POST to the UCM's "New" HTTPS API.
On Grandstream GXV3611IRHD before 1.0.3.23 devices, the root account lacks a password.
Shell Metacharacter Injection in the SSH configuration interface on Grandstream GXP16xx VoIP 1.0.4.128 phones allows attackers to execute arbitrary system commands and gain a root shell.
An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
An unauthenticated stack-based buffer overflow vulnerability exists in the HTTP API endpoint /cgi-bin/api.values.get. A remote attacker can leverage this vulnerability to achieve unauthenticated remote code execution (RCE) with root privileges on a target device. The vulnerability affects all six device models in the series: GXP1610, GXP1615, GXP1620, GXP1625, GXP1628, and GXP1630.
The HTTP interface of the Grandstream UCM6200 series is vulnerable to an unauthenticated remote SQL injection via crafted HTTP request. An attacker can use this vulnerability to execute shell commands as root on versions before 1.0.19.20 or inject HTML in password recovery emails in versions before 1.0.20.17.
The UCM6200 series 1.0.20.22 and below stores unencrypted user passwords in an SQLite database. This could allow an attacker to retrieve all passwords and possibly gain elevated privileges.
Grandstream GAC2500 1.0.3.35, GXP2200 1.0.3.27, GVC3202 1.0.3.51, GXV3275 before 1.0.3.219 Beta, and GXV3240 before 1.0.3.219 Beta devices allow unauthenticated remote code execution via shell metacharacters in a /manager?action=getlogcat priority field, in conjunction with a buffer overflow (via the phonecookie cookie) to overwrite a data structure and consequently bypass authentication. This can be exploited remotely or via CSRF because the cookie can be placed in an Accept HTTP header in an XMLHttpRequest call to lighttpd.
A Malformed Input String to /cgi-bin/deleteCA on Grandstream GXP16xx VoIP 1.0.4.128 phones allows attackers to delete configuration parameters and gain admin access to the device.
In Grandstream GSD3710 in its 1.0.11.13 version, it's possible to overflow the stack since it doesn't check the param length before using the sscanf instruction. Because of that, an attacker could create a socket and connect with a remote IP:port by opening a shell and getting full access to the system. The exploit affects daemons dbmng and logsrv that are running on ports 8000 and 8001 by default.
an attacker with knowledge of user/pass of Grandstream GSD3710 in its 1.0.11.13 version, could overflow the stack since it doesn't check the param length before use the strcopy instruction. The explotation of this vulnerability may lead an attacker to execute a shell with full access.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allows Command Injection as root in its administrative web interface.
An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdbdebugserver variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
Multiple buffer overflows in the limited configuration shell (/sbin/gsconfig) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manageif setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.
Grandstream GWN7000 before 1.0.6.32 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/uci.apply updatendswebrootfromtmp API call.
Grandstream UCM6204 before 1.0.19.20 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the backupUCMConfig file-backup parameter to the /cgi? URI.
An issue was discovered in Grandstream GXP14XX 1.0.8.9 and GXP16XX 1.0.7.13, allows remote attackers to escalate privileges via incorrect access control using an end-user session-identity token.
The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.
Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests.
Grandstream GXP1600 series firmware 1.0.4.152 and below is vulnerable to authenticated remote command execution when an attacker uploads a specially crafted tar file to the HTTP /cgi-bin/uploadvpntar interface.
Grandstream GXP1600 series firmware 1.0.4.152 and below is vulnerable to authenticated remote command execution when an attacker adds an OpenVPN up script to the phone's VPN settings via the "Additional Settings" field in the web interface. When the VPN's connection is established, the user defined script is executed with root privileges.
Grandstream GXV3370 before 1.0.1.41 and WP820 before 1.0.3.6 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in a /manager?action=getlogcat priority field.
Grandstream UCM6204 before 1.0.19.20 devices allow remote authenticated users to conduct SQL injection attacks via the sord parameter in a listCodeblueGroup API call to the /cgi? URI.