Hitachi Energy UnemAn authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component t…

First published (updated )

Hitachienergy Relion 670 FirmwarePath Traversal

First published (updated )

Hitachienergy Rtu500Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series

First published (updated )

Hitachi Energy Microscada X Sys600A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...

First published (updated )

Hitachi Energy Microscada X Sys600A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any da ...

First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Hitachi Energy Foxman UnA user/password reuse vulnerability exists in the FOXMAN-UN/UNEM application and server management. …

First published (updated )

Hitachi Energy Microscada Pro Sys600Path Traversal

First published (updated )

Hitachi Energy Microscada Pro Sys600A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited …

First published (updated )

Hitachi Energy SDM600SDM600 file permission validation

First published (updated )

Hitachi Energy Foxman UnBuffer Overflow

First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Hitachi Energy Unemvulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could …

First published (updated )

Hitachi Energy Microscada X Sys600The product exposes a service that is intended for local only to all network interfaces without any …

EPSS
0.09%
First published (updated )

Hitachi Energy EsomsABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonym…

First published (updated )

Hitachi Energy Microscada Pro Sys600ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function

First published (updated )

Hitachi Energy Foxman UnUse of default key for encryption

First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Hitachi Energy Foxman UnThe affected products store public and private key that are used to sign and protect custom parameter set files from modification.

First published (updated )

Hitachi Energy Foxman UnCommunication between the client and server partially using CORBA over TCP/IP

First published (updated )

Hitachi Energy SDM600SDM600 API permission check

First published (updated )

Hitachienergy Relion 670 FirmwareInsufficient Security Control Vulnerability

First published (updated )

Hitachi Energy Fox615Weak default credential associated with TCP port 26

First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Hitachi Energy Asset SuiteA vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On …

8.8
First published (updated )

Hitachi Energy Microscada X Sys600Input Validation Vulnerability in Hitachi Energy’s MicroSCADA Pro/X SYS600 Products

8.8
First published (updated )

Hitachi Energy EllipseAn Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 …

8.8
First published (updated )

Hitachienergy Modular Switchgear Monitoring FirmwareHTTP Response Splitting in Hitachi Energy’s MSM Product

8.8
First published (updated )

Hitachienergy Modular Switchgear Monitoring FirmwareCross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product

8.8
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Hitachi Energy Microscada X Sys600A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authenticated user's role.

8.8
First published (updated )

Hitachi Energy Fox615SSH activation problem in the proprietary management protocol (port TCP 5558)

8.6
First published (updated )

Hitachi Energy Microscada X Sys600An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the se…

8.2
First published (updated )

Hitachienergy Relion 670 FirmwareInsufficient Security Control Vulnerability

8.1
First published (updated )

Hitachienergy Relion 670 FirmwareInput Validation

7.8
First published (updated )

Never miss a vulnerability like this again

Sign up to SecAlerts for real-time vulnerability data matched to your software, aggregated from hundreds of sources.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2025 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203