iconics and mitsubishi electric iconics suite including genesis64, hyper historian, analytix, and mobilehmi for cve-2022-23127 (cross-site scripting cwe-79) all versions up to and including 10.96.2 for cve-2022-23128 (incomplete list of disallowed inputs cwe-184) all versions from 10.95.3 to 10.97 for cve-2022-23129 (plaintext storage of a password cwe-256) all versions from 10.90 to 10.97 for cve-2022-23130 (buffer over-read cwe-126) all versions up to and including 10.97
4
iconics and mitsubishi electric mitsubishi electric mc works64 for cve-2022-23127 (cross-site scripting cwe-79) all versions prior to 4.04e (10.95.210.01) for cve-2022-23128 (incomplete list of disallowed inputs cwe-184) mc works64: version 4.00a (v10.95.201.23) to 4.04e (v10.95.210.01) for cve-2022-23129 (plaintext storage of a password cwe-256) all versions prior to 4.04e (10.95.210.01) for cve-2022-23130 (buffer over-read cwe-126) mc works64: version 4.00a (v10.95.201.23) to 4.04e (v10.95.210.01)
4
iconics and mitsubishi electric
3
iconics and mitsubishi electric suite
3
iconics and mitsubishi electric all versions from 10.90 to 10.97
1
iconics and mitsubishi electric all versions from 10.95.3 to 10.97
1
iconics and mitsubishi electric all versions prior to 4.04e (10.95.210.01)
1
iconics and mitsubishi electric all versions up to and including 10.96.2
1
iconics and mitsubishi electric all versions up to and including 10.97
1
iconics and mitsubishi electric for cve-2022-23127 (cross-site scripting cwe-79) all versions prior to 4.04e (10.95.210.01)
1
iconics and mitsubishi electric for cve-2022-23127 (cross-site scripting cwe-79) all versions up to and including 10.96.2
1
iconics and mitsubishi electric for cve-2022-23128 (incomplete list of disallowed inputs cwe-184) all versions from 10.95.3 to 10.97
1
iconics and mitsubishi electric for cve-2022-23128 (incomplete list of disallowed inputs cwe-184) mc works64: version 4.00a (v10.95.201.23) to 4.04e (v10.95.210.01)
1
iconics and mitsubishi electric for cve-2022-23129 (plaintext storage of a password cwe-256) all versions from 10.90 to 10.97
1
iconics and mitsubishi electric for cve-2022-23129 (plaintext storage of a password cwe-256) all versions prior to 4.04e (10.95.210.01)
1
iconics and mitsubishi electric for cve-2022-23130 (buffer over-read cwe-126) all versions up to and including 10.97
1
iconics and mitsubishi electric for cve-2022-23130 (buffer over-read cwe-126) mc works64: version 4.00a (v10.95.201.23) to 4.04e (v10.95.210.01)
1
iconics and mitsubishi electric mc works64: version 4.00a (v10.95.201.23) to 4.04e (v10.95.210.01)
1
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.

First published (updated )
Severity
6.1
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.

First published (updated )
Severity
7.7
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.

First published (updated )
Severity
5.9
AV:A/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H

Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.97 and prior and ICONICS Hyper Historian versions 10.97 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64 or MC Works64 and execute commands against the database from GENESIS64 or MC Works64.

1 / 2
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.