Where
-Infinity
0

Vendor Risk Score

See how mitsubishi compares to other vendors in security performance

View Risk Score →

Software

mitsubishi electric melipc series mi5122-vw cpu firmware
4
mitsubishi electric melsec iq-r series r16psfcpu
4
mitsubishi electric melsec iq-r08psfcpu firmware
4
mitsubishi melipc mi5122-vw firmware
4
mitsubishi melsec iq-r r00 cpu firmware
4
mitsubishi melsec iq-r r01 cpu firmware
4
mitsubishi melsec iq-r r02 cpu
4
mitsubishi melsec iq-r r02 cpu firmware
4
mitsubishi melsec iq-r r04 cpu firmware
4
mitsubishi melsec iq-r r04 pcpu firmware
4
mitsubishi melsec iq-r r08 cpu firmware
4
mitsubishi melsec iq-r r08 sfcpu firmware
4
mitsubishi melsec iq-r r12 ccpu-v
4
mitsubishi melsec iq-r r12 ccpu-v firmware
4
mitsubishi melsec iq-r r120 cpu
4
mitsubishi melsec iq-r r120 cpu firmware
4
mitsubishi melsec iq-r r120 sfcpu
4
mitsubishi melsec iq-r r16 cpu firmware
4
mitsubishi melsec iq-r r16 sfcpu
4
mitsubishi melsec iq-r r16 sfcpu firmware
4
mitsubishi melsec iq-r r32 cpu
4
mitsubishi melsec iq-r r32 cpu firmware
4
mitsubishi melsec iq-r r32 mtcpu firmware
4
mitsubishi ae-200a firmware
3
mitsubishi ae-200e
3
mitsubishi ae-200e firmware
3
mitsubishi ae-50a
3
mitsubishi ae-50e firmware
3
mitsubishi ag-150a-a
3
mitsubishi ag-150a-j
3
mitsubishi eb-50gu-a
3
mitsubishi eb-50gu-a firmware
3
mitsubishi eb-50gu-j
3
mitsubishi eb-50gu-j firmware
3
mitsubishi electric melsec iq-r08
3
mitsubishi electric melsec iq-r120pcpu firmware
3
mitsubishi electric melsec iq-r16pcpu firmware
3
mitsubishi electric melsec q series q26dhccpu-ls
3
mitsubishi electric melsec q-q03udecpu firmware
3
mitsubishi electric melsec q-q03udvcpu
3
mitsubishi electric melsec q-q03udvcpu firmware
3
mitsubishi electric melsec q-q06udpvcpu
3
mitsubishi electric melsec q-q06udpvcpu firmware
3
mitsubishi electric melsec q-q172dcpu-s1
3
mitsubishi electric melsec q-q172dcpu-s1 firmware
3
mitsubishi electric melsec q-q172dscpu
3
mitsubishi electric melsec q-q172dscpu firmware
3
mitsubishi electric melsec q-q173dcpu
3
mitsubishi electric melsec q-q173dcpu-s1 firmware
3
mitsubishi electric melsec q-q173dscpu firmware
3
Severity
5.5
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU Firmware versions "32" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "65" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "29" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior, Mitsubishi Electric Corporation MELSEC iQ-L Series L04/08/16/32HCPU Firmware versions "05" and prior and Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition in Ethernet communication on the module by sending specially crafted packets. A system reset of the module is required for recovery.

1 / 2
Source: MITRE
First published (updated )
Severity
7.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N

Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability.

First published (updated )
Severity
7.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.

1 / 2
First published (updated )
Severity
7.8
Input Validation
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.

1 / 2
First published (updated )
Severity
7.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "28" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions "29" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version "23" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions "16" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. "23071" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. "24031" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version "F" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version "W" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. "23121" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. "23121" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.

1 / 2
First published (updated )
Severity
8.5
XEE
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H

Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.

First published (updated )
Severity
7.5
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Buffer access with incorrect length value vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.38.000, GT25 model communication driver versions 01.19.000 through 01.38.000, GT23 model communication driver versions 01.19.000 through 01.38.000 and GT21 model communication driver versions 01.21.000 through 01.39.000, GOT SIMPLE series GS21 model communication driver versions 01.21.000 through 01.39.000, GT SoftGOT2000 versions 1.170C through 1.250L and Tension Controller LE7-40GU-L Screen package data for MODBUS/TCP V1.00 allows a remote unauthenticated attacker to stop the communication function of the products via specially crafted packets.

First published (updated )
Severity
10
Input Validation
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Improper Input Validation vulnerability in Mitsubishi Electric MELSEC-Q Series QJ71E71-100 first 5 digits of serial number "24061" or prior, Mitsubishi Electric MELSEC-L series LJ71E71-100 first 5 digits of serial number "24061" or prior and Mitsubishi Electric MELSEC iQ-R Series RD81MES96N firmware version "08" or prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on the target products by sending specially crafted packets.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203