See how mitsubishielectric compares to other vendors in security performance
Improper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and Mitsubishi Electric GOT2000 Series GT23 model FTP server versions 01.39.000 and prior allows a remote authenticated attacker to cause a Denial of Service condition by sending specially crafted command.
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Resource Management Errors vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functions or execute malware via a specially crafted packet.
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors.
When MELSOFT transmission port (UDP/IP) of Mitsubishi Electric MELSEC iQ-R series (all versions), MELSEC iQ-F series (all versions), MELSEC Q series (all versions), MELSEC L series (all versions), and MELSEC F series (all versions) receives massive amount of data via unspecified vectors, resource consumption occurs and the port does not process the data properly. As a result, it may fall into a denial-of-service (DoS) condition. The vendor states this vulnerability only affects Ethernet communication functions.
Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/13/26UDPVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q12DCCPU-V all versions, Mitsubishi Electric MELSEC-Q Series Q24DHCCPU-V(G) all versions, Mitsubishi Electric MELSEC-Q Series Q24/26DHCCPU-LS all versions, Mitsubishi Electric MELSEC-L series L02/06/26CPU(-P) the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-L series L26CPU-(P)BT the first 5 digits of serial number "24051" and prior and Mitsubishi Electric MELIPC Series MI5122-VW firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition in Ethernet communications by sending specially crafted packets. A system reset of the products is required for recovery.
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the function is running.
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the function is running.
Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server.
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server.
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.97 and prior and ICONICS Hyper Historian versions 10.97 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64 or MC Works64 and execute commands against the database from GENESIS64 or MC Works64.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.