-Infinity
0
Severity
10
EPSS
0.04%
AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

PTC Creo Elements/Direct License Server exposes a web interface which can be used by unauthenticated remote attackers to execute arbitrary OS commands on the server.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
9.9
Malicious File Upload
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

A user could use the “Upload Resource” functionality to upload files to any location on the disk.

Remedy

PTC recommends users upgrade to Vuforia Studio release 9.9 https://support.ptc.com/help/vuforia/studio/en/ or higher.
First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.

First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
9.8
Integer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.

1 / 2
Source: MITRE

Remedy

PTC has released the following resolutions: Update the impacted product to the latest version: ·         ThingWorx Edge C-SDK: 3.0.0 or later. ·         ThingWorx Edge MicroServer (EMS): v5.4.11 or later. ·         .NET-SDK: v5.8.5 or later. For Kepware products, the vulnerability is mitigated if the ThingWorx Interface is not enabled. To use the ThingWorx Interface without the vulnerability, update to the latest version of the product: ·         Kepware KEPServerEX: v6.13 or later. ·         ThingWorx Kepware Server (formerly ThingWorx Industrial Connectivity): v6.13 or later. ·         ThingWorx Kepware Edge: v1.6 or later. The following products should be upgraded as indicated or in accordance with the applicable organization’s recommendations if the ThingWorx Interface is in use: ·         Rockwell Automation KEPServer Enterprise: v6.13 or later. ·         GE Digital Industrial Gateway Server: v7.613 or later. For more information see PTC’s Customer Support Article .
First published (updated )
Severity
9.8
Out-of-bounds Read
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.

Remedy

PTC has released the following resolutions: Update the impacted product to the latest version: ·         ThingWorx Edge C-SDK: 3.0.0 or later. ·         ThingWorx Edge MicroServer (EMS): v5.4.11 or later. ·         .NET-SDK: v5.8.5 or later. For Kepware products, the vulnerability is mitigated if the ThingWorx Interface is not enabled. To use the ThingWorx Interface without the vulnerability, update to the latest version of the product: ·         Kepware KEPServerEX: v6.13 or later. ·         ThingWorx Kepware Server (formerly ThingWorx Industrial Connectivity): v6.13 or later. ·         ThingWorx Kepware Edge: v1.6 or later. The following products should be upgraded as indicated or in accordance with the applicable organization’s recommendations if the ThingWorx Interface is in use: ·         Rockwell Automation KEPServer Enterprise: v6.13 or later. ·         GE Digital Industrial Gateway Server: v7.613 or later. For more information see PTC’s Customer Support Article .
First published (updated )
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.

1 / 2
First published (updated )
Severity
9.3
EPSS
0.50%
Code Injection
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red

A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data.

This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0.

First published (updated )
Severity
9.3
3 Months
Input Validation
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:X/U:Red

A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill PDMlink and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data.  This advisory also applies to all CPS versions The identified vulnerability also impacts Windchill and FlexPLM releases prior to 11.0 M030

1 / 2
Source: MITRE
First published (updated )
Severity
9.3
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:M/U:Red

A critical bypass access control vulnerability has been reported in PTC Windchill Risk and Reliability (WRR) Enterprise Edition.

First published (updated )
Severity
9.2
Input Validation
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red

A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data.

First published (updated )
Severity
9.1
Use After Free, Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.

First published (updated )
Severity
9.1
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.

First published (updated )
Severity
9.1
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.

1 / 2
First published (updated )
Severity
9.1
EPSS
0.07%
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.

Remedy

PTC has released and recommends users to update to the following versions: * KEPServerEX should upgrade to v6.15 or later * ThingWorx Kepware Server should upgrade to v6.15 or later * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later * OPC-Aggregator should upgrade to v6.15 or later * ThingWorx Kepware Edge: Upgrade to v1.8 or later Refer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide If additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log For more information, see PTC's advisory https://www.ptc.com/en/support/article/CS405439 .
First published (updated )
Severity
8.8
XSS
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

?If an attacker tricks an admin user of PTC Codebeamer into clicking on a malicious link, it may allow the attacker to inject arbitrary code to be executed in the browser on the target device.

1 / 2

Remedy

PTC recommends the following: * ​Version 22.10.X: upgrade to 22.10-SP8 https://intland.com/codebeamer-download/  or newer version * ​Version 22.04.X: upgrade to 22.04-SP6 https://intland.com/codebeamer-download/  or newer version * ​Version 21.09.X: upgrade to 21.09-SP14 https://intland.com/codebeamer-download/  or newer version ​Docker Image download: https://hub.docker.com/r/intland/codebeamer/tags https://hub.docker.com/r/intland/codebeamer/tags ​Codebeamer installers: https://intland.com/codebeamer-download/ https://intland.com/codebeamer-download/ ​Hosted customers may request an upgrade through the support channel https://codebeamer.com/cb/tracker/1910563 . ​Note that version 2.0 is not impacted by this vulnerability. ​For more information refer to PTC Security Advisory and Resolution https://codebeamer.com/cb/wiki/31346480 .
First published (updated )
Severity
8.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H

By changing the filename parameter in the request, an attacker could delete any file with the permissions of the Vuforia server account.

Remedy

PTC recommends users upgrade to Vuforia Studio release 9.9 https://support.ptc.com/help/vuforia/studio/en/ or higher.
First published (updated )
Severity
8
CSRF
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

PTC Vuforia Studio does not require a token; this could allow an attacker with local access to perform a cross-site request forgery attack or a replay attack.

Remedy

PTC recommends users upgrade to Vuforia Studio release 9.9 https://support.ptc.com/help/vuforia/studio/en/ or higher.
First published (updated )
Severity
7.8
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM.

First published (updated )
Severity
7.7
SSRF
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:D/RE:M/U:Red

A Server-Side Request Forgery (SSRF) vulnerability has been reported in PTC Windchill PDMLink and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data.

First published (updated )
Severity
7.5
Buffer Overflow
AV:N/AC:L/Au:N/C:P/I:P/A:P

Heap-based buffer overflow in the browser plugin for PTC Creo View allows remote attackers to execute arbitrary code via vectors involving setting a large buffer to an unspecified attribute.

First published (updated )
Severity
7.5
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

An issue was discovered in PTC ThingWorx Platform 6.5 through 8.2. There is a hardcoded encryption key.

First published (updated )
Severity
7.5
Path Traversal
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

PTC ThingWorx Platform through 8.3.0 is vulnerable to a directory traversal attack on ZIP files via a POST request.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) when receiving certain input throws an exception. Services using said function do not handle the exception. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to crash the affected product.

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
7.5
Path Traversal
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) (disregarding Axeda agent v6.9.2 and v6.9.3) is vulnerable to directory traversal, which could allow a remote unauthenticated attacker to obtain file system read access via web server..

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service.

Remedy

PTC recommends the following: Upgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent. Configure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255 Provide a unique password in the AxedaDesktop.ini file for each unit. Never use ERemoteServer in production. Make sure to delete ERemoteServer file from host device. Remove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi When running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others. When running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255 Configure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255 PTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215 The Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required.
First published (updated )
Severity
7.5
EPSS
0.10%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

PTC’s KEPServerEX Versions 6.0 to 6.14.263 are vulnerable to being made to read a recursively defined object that leads to uncontrolled resource consumption. KEPServerEX uses OPC UA, a protocol which defines various object types that can be nested to create complex arrays. It does not implement a check to see if such an object is recursively defined, so an attack could send a maliciously created message that the decoder would try to decode until the stack overflowed and the device crashed.

First published (updated )
Severity
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

The local Vuforia web application does not support HTTPS, and federated credentials are passed via basic authentication.

Remedy

PTC recommends users upgrade to Vuforia Studio release 9.9 https://support.ptc.com/help/vuforia/studio/en/ or higher.
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203