Where
-Infinity
0

Vendor Risk Score

See how rockwellautomation compares to other vendors in security performance

View Risk Score →

Software

rockwellautomation micrologix 1400
13
rockwellautomation arena
10
rockwellautomation micrologix 1400 b firmware
10
rockwellautomation armorstart lt
9
rockwellautomation armorstart lt firmware
9
rockwellautomation factorytalk assetcentre
8
rockwellautomation 1756-enbt
7
rockwellautomation micrologix 1100 firmware
7
rockwellautomation 1756-eweb
6
rockwellautomation 1768-enbt
6
rockwellautomation 1768-eweb
6
rockwellautomation factorytalk services platform
6
rockwellautomation 1794-aentr flex i\/o ethernet\/ip adapter
5
rockwellautomation allen-bradley armorstratix 5700
5
rockwellautomation allen-bradley stratix 5400
5
rockwellautomation allen-bradley stratix 5410
5
rockwellautomation allen-bradley stratix 5700
5
rockwellautomation allen-bradley stratix 8000
5
rockwellautomation compactlogix
5
rockwellautomation compactlogix controllers
5
rockwellautomation compactlogix l32e controller
5
rockwellautomation compactlogix l35e controller
5
rockwellautomation controllogix
5
rockwellautomation controllogix controllers
5
rockwellautomation factorytalk linx
5
rockwellautomation flexlogix 1788-enbt adapter
5
rockwellautomation guardlogix
5
rockwellautomation guardlogix controllers
5
rockwellautomation micrologix
5
rockwellautomation micrologix 1100
5
rockwellautomation micrologix 1400 a firmware
5
rockwellautomation softlogix
5
rockwellautomation softlogix controllers
5
rockwellautomation 1763-l16awa series a
4
rockwellautomation 1763-l16awa series b
4
rockwellautomation 1763-l16bbb series a
4
rockwellautomation 1763-l16bbb series b
4
rockwellautomation 1763-l16bwa series a
4
rockwellautomation 1763-l16bwa series b
4
rockwellautomation 1763-l16dwd series a
4
rockwellautomation 1763-l16dwd series b
4
rockwellautomation 1766-l32awa series a
4
rockwellautomation 1766-l32awa series b
4
rockwellautomation 1766-l32awaa series a
4
rockwellautomation 1766-l32awaa series b
4
rockwellautomation 1766-l32bwa series a
4
rockwellautomation 1766-l32bwa series b
4
rockwellautomation 1766-l32bwaa series a
4
rockwellautomation 1766-l32bwaa series b
4
rockwellautomation 1766-l32bxb series a
4
Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Cisco IOS XE Web UI contains a privilege escalation vulnerability in the web user interface that could allow a remote, unauthenticated attacker to create an account with privilege level 15 access. The attacker can then use that account to gain control of the affected device.

1 / 3
Source: CISA
First published (updated )
Severity
10
Buffer Overflow
AV:N/AC:L/Au:N/C:C/I:C/A:C

Buffer overflow in LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a UDP packet with a certain integer length value that is (1) too large or (2) too small, leading to improper handling by Logger.dll.

First published (updated )
Severity
10
Buffer Overflow
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request.

First published (updated )
Severity
10
AV:N/AC:L/Au:N/C:C/I:C/A:C

Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Requests a specific set of bytes from an undocumented data file and returns the ASCII version of the master password.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG (also RUN for some) Description: Allows an attacker to enable SNMP, Modbus, DNP, and any other features in the channel configuration. Also allows attackers to change network parameters, such as IP address, name server, and domain name.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0012 Fault Type: Non-User Description: A fault state can be triggered by overwriting the ladder logic data file (type 0x22 number 0x02) with null values.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Any input or output can be forced, causing unpredictable activity from the PLC.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Live rung edits are able to be made by an unauthenticated user allowing for addition, deletion, or modification of existing ladder logic. Additionally, faults and cpu state modification can be triggered if specific ladder logic is used.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed.

First published (updated )
Severity
10
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: The filetype 0x03 allows users write access, allowing the ability to overwrite the Master Password value stored in the file.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Codes: 0023, 002e, and 0037 Fault Type: Recoverable Description: The STI, EII, and HSC function files contain bits signifying whether or not a fault has occurred. Additionally there is a bit signaling the module to auto start. When these bits are set for any of the three modules and the device is moved into a run state, a fault is triggered.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.

First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: This ability is leveraged in a larger exploit to flash custom firmware.

First published (updated )
Severity
10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Reads the encoded ladder logic from its data file and print it out in HEX.

First published (updated )
Severity
10
Buffer Overflow
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.

First published (updated )
Severity
10
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )
Severity
10
SQL Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A vulnerability exists in the RunSearch function of SearchService service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier, which may allow for the execution of remote unauthenticated arbitrary SQL statements.

Remedy

Rockwell Automation encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559

Remedy

As an additional mitigation, Rockwell Automation encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203