See how siemens compares to other vendors in security performance
A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system's infrastructure, including details on all devices, substations, users, and scheduled activities.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization.
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3). The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation.
A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.62). Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.
A vulnerability has been identified in Siemens Software Center (All versions). The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application.
HID: core: zero-initialize the report buffer
A stored cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS® software enables a malicious authenticated administrator to store a JavaScript payload using the web interface.
This issue is applicable to PAN-OS software on PA-Series and VM-Series firewalls and on Panorama (virtual and M-Series).
Cloud NGFW and Prisma® Access are not impacted by this vulnerability.
A vulnerability was found in curl. This issue occurs because the number of acceptable "links" in the "decompression chain" was unbounded, allowing a malicious server to insert a virtually unlimited number of compression steps. This flaw leads to a denial of service, either by mistake or by a malicious actor.
A malicious server can serve excessive amounts of Set-Cookie: headers in a HTTP response to curl and curl < 7.84.0 stores all of them. A sufficiently large amount of (big) cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger than the threshold that curl uses internally to avoid sending crazy large requests (1048576 bytes) and instead returns an error.This denial state might remain for as long as the same cookies are kept, match and haven't expired. Due to cookie matching rules, a server on foo.example.com can set cookies that also would match for bar.example.com, making it it possible for a "sister server" to effectively cause a denial of service for a sibling site on the same second level domain using this method.
A flaw was found in expat. A stack exhaustion in doctype parsing could be triggered by a file with a large number of opening braces, resulting in a denial of service.
A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly validate input in the web server's JSON-RPC interface. This could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges.
A flaw was found in curl. The flaw lies in how curl handles cached or pipelined responses that it receives from either a IMAP, POP3, SMTP or FTP server before the TLS upgrade using STARTTLS. In such a scenario curl even after upgrading to TLS would trust these cached responses treating them as valid and authenticated and use them. An attacker could potentially use this flaw to carry out a Man-In-The-Middle attack. The highest threat from this vulnerability is to data confidentiality.
A flaw was found in the way curl handled telnet protocol option for sending environment variables, which could lead to sending of uninitialized data from a stack-based buffer to the server. This issue leads to potentially revealing sensitive internal information to the server using a clear-text network protocol.
A flaw was found in curl in the way curl handles a file hash mismatch after downloading content using the Metalink feature. This flaw allows malicious actors controlling a hosting server to trick users into downloading malicious content. The highest threat from this vulnerability is to integrity.
A flaw was found in curl in the way curl handles credentials when downloading content using the Metalink feature. This flaw allows malicious actors controlling a hosting server to gain access to credentials provided while downloading content without the user's knowledge. The highest threat from this vulnerability is to confidentiality.
curl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the target of the second HTTP request.
A flaw was found in the way libcurl handled TLS 1.3 session tickets. A malicious HTTPS proxy could possibly use this flaw to make libcurl resume a TLS session it previously had with the proxy while intending to resume a TLS session with a target server, making it possible for the proxy to perform a man-in-the-middle attack.
curl 7.61.0 through 7.76.1 suffers from exposure of data element to wrong session due to a mistake in the code for CURLOPTSSLCIPHERLIST when libcurl is built to use the Schannel TLS library. The selected cipher set was stored in a single "static" variable in the library, which has the surprising side-effect that if an application sets up multiple concurrent transfers, the last one that sets the ciphers will accidentally control the set used by all transfers. In a worst-case scenario, this weakens transport security significantly.
In SQLite before 3.32.3 select.c mishandles query-flattener optimization leading to a multiSelectOrderBy heap overflow because of misuse of transitive properties for constant propagation.
ext/fts3/fts3snippet.c in SQLite before 3.32.0 has a NULL pointer dereference via a crafted matchinfo() query.
Last updated 25 August 2025
Last updated 25 August 2025
alter.c in SQLite through 3.30.1 allows attackers to trigger infinite recursion via certain types of self-referential views in conjunction with ALTER TABLE statements.
An issue was discovered in OpenSSH 7.9. Due to the scp implementation being derived from 1983 rcp, the server chooses which files/directories are sent to the client. However, the scp client only performs cursory validation of the object name returned (only directory traversal attacks are prevented). A malicious scp server (or Man-in-The-Middle attacker) can overwrite arbitrary files in the scp client target directory. If recursive operation (-r) is performed, the server can manipulate subdirectories as well (for example, to overwrite the .ssh/authorizedkeys file).
An issue was discovered in OpenSSH 7.9. Due to missing character encoding in the progress display, a malicious server (or Man-in-The-Middle attacker) can employ crafted object names to manipulate the client output, e.g., by using ANSI control codes to hide additional files being transferred. This affects refreshprogressmeter() in progressmeter.c.