Where
-Infinity
0
Severity
9.4
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Cleartext transmission in the primary control endpoints of Teledyne FLIR Aware2 versions through 6.9.0.2 allows remote unauthenticated attackers to intercept, hijack, or modify session traffic against Teledyne FLIR PackBot robots running this software via sniffing or hijacking network traffic.

First published (updated )
Severity
7.1
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Missing authentication in the web interface in Teledyne FLIR Aware2 versions through 6.9.0.2 allows remote unauthenticated attackers to achieve denial of service against Teledyne FLIR PackBot robots running this software via misuse of the reboot endpoint.

First published (updated )
Severity
10
Path Traversal
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Unvalidated pathnames in the web interface in Teledyne FLIR Aware2 versions through 6.9.0.2 (PackBot) and 1.7.9 (FirstLook) allows remote unauthenticated attackers to read configuration and security parameters on Teledyne FLIR PackBot and FirstLook robots running this software via path traversal.

First published (updated )
Severity
5.3
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:L/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Unencrypted traffic in the 802.11 network of Teledyne FLIR Aware2 versions through 6.9.0.2 allows adjacent unauthenticated attackers to intercept, hijack, or modify session traffic against Teledyne FLIR PackBot robots running this software via sniffing or hijacking network traffic.

First published (updated )
Severity
9.4
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Hardcoded passwords in the access control in Teledyne FLIR Aware2 versions through 6.9.0.2 (PackBot) and 1.7.9 (FirstLook) allows remote unauthenticated attackers to access and reconfigure Teledyne FLIR PackBot and FirstLook robots running this software via reading the passwords from the firmware or documentation.

First published (updated )
Severity
8.5
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Cleartext transmission without a cryptographic integrity check in operator control unit to robot UDP traffic in Teledyne FLIR Aware2 versions through 6.9.0.2 (PackBot) and 1.7.9 (FirstLook) allows adjacent unauthenticated attackers to intercept, hijack, or modify control traffic against Teledyne FLIR PackBot and FirstLook robots running this software via sniffing or hijacking network traffic.

First published (updated )
Severity
2.3
EPSS
1.53%
Command Injection
AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:R

A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been declared as critical. This vulnerability affects the function sendCommand of the file runcmd.sh. The manipulation of the argument cmd leads to command injection. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The researcher highlights, that "[a]lthough this functionality is currently disabled due to server CGI configuration errors, it is essentially a 'time bomb' waiting to be activated". The vendor was contacted early about this disclosure but did not respond in any way.

First published (updated )
Severity
5.5
EPSS
0.06%
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R

A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16 and classified as critical. Affected by this issue is some unknown functionality of the file /priv/production/production.html of the component Production Tools. The manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

First published (updated )
Severity
2.9
EPSS
0.04%
AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R

A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

First published (updated )
Severity
2.1
EPSS
0.04%
Malicious File Upload
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C

A vulnerability was detected in Teledyne FLIR AX8 up to 1.46. Affected by this vulnerability is an unknown functionality of the file /upload.php. Performing manipulation of the argument File results in unrestricted upload. It is possible to initiate the attack remotely. The exploit is now public and may be used. Upgrading to version 1.49.16 addresses this issue. Upgrading the affected component is recommended. The vendor points out: "FLIR AX8 internal web site has been refactored to be able to handle the reported vulnerabilities."

First published (updated )
Severity
3.4
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N

An issue was discovered in Teledyne FLIR M300 2.00-19. User account passwords are encrypted locally, and can be decrypted to cleartext passwords using the utility umSetup. This utility requires root permissions to execute.

First published (updated )
Severity
9.8
SSRF
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An issue was discovered in Teledyne FLIR M300 2.00-19. Unauthenticated remote code execution can occur in the web server. An attacker can exploit this by sending a POST request to the vulnerable PHP page. An attacker can elevate to root permissions with Sudo.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203