-Infinity
0
Severity
6.5
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Tenda AX3 v16.03.12.11 contains a stack overflow in formSetIptv via the iptvType parameter, which can cause memory corruption and enable remote code execution (RCE).

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

First published (updated )
Severity
8.9
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A weakness has been identified in Tenda WH450 1.0.0.18. Affected by this vulnerability is an unknown functionality of the file /goform/CheckTools of the component HTTP Request Handler. This manipulation of the argument ipaddress causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.

First published (updated )
Severity
8.9
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security vulnerability has been detected in Tenda WH450 1.0.0.18. Affected by this issue is some unknown functionality of the file /goform/L7Im of the component HTTP Request Handler. Such manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field serviceName) to /goform/AdvSetMacMtuWan.

First published (updated )
Severity
6.5
Buffer Overflow
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field serverName) to /goform/AdvSetMacMtuWan.

First published (updated )
Severity
2.1
Command Injection
AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R

A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.

First published (updated )
Severity
2.1
Command Injection
AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R

A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function formexeCommand of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this issue is the function strcpy of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapskcrypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifichkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was determined in Tenda CH22 1.0.0.1. This vulnerability affects the function formWrlExtraGet of the file /goform/GstDhcpSetSer. This manipulation of the argument dips causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.

First published (updated )
Severity
2.1
Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R

A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The affected element is the function sscanf of the file /goform/fastsettingwifiset. The manipulation of the argument timeZone leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fastsettingpppoeset. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.

First published (updated )
Severity
7.4
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing a manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.

First published (updated )
Severity
8.9
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mitssidindex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.

First published (updated )
Severity
8.9
Buffer Overflow
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R

A vulnerability was found in Tenda CH22 1.0.0.1. This affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. Performing a manipulation of the argument page results in memory corruption. The attack is possible to be carried out remotely. The exploit has been made public and could be used.

First published (updated )
Severity
2.1
Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R

A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203