See how unitronics compares to other vendors in security performance
Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.
This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
: Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.
This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.
This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.
This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
Unitronics Vision PLC – CWE-703: Improper Check or Handling of Exceptional Conditions may allow denial of service
Unitronics Vision PLC –
CWE-676: Use of Potentially Dangerous Function may allow security feature bypass
Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication.
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-259: Use of Hard-coded Password may allow disclosing Sensitive Information Embedded inside Device's Firmware
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-348: Use of Less Trusted Source may allow RCE
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-78: 'OS Command Injection' may allow RCE
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-22: 'Path Traversal' may allow RCE
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-23: Relative Path Traversal
Unitronics Unistream Unilogic – Versions prior to 1.35.227 -
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor may allow Taking Ownership Over Devices
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-22: 'Path Traversal' may allow RCE
CWE-287: Improper Authentication may allow Authentication Bypass
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.
Stack-based buffer overflow in Unitronics VisiLogic OPLC IDE before 9.8.30 allows remote attackers to execute arbitrary code via a crafted filename field in a ZIP archive in a vlp file.
Heap-based buffer overflow in Unitronics VisiLogic OPLC IDE before 9.8.09 allows remote attackers to execute arbitrary code via a long vlp filename.
Unitronics VisiLogic OPLC IDE before 9.8.02 allows remote attackers to execute unspecified code via unknown vectors.
Unitronics VisiLogic OPLC IDE before 9.8.02 does not properly restrict access to ActiveX controls, which allows remote attackers to have an unspecified impact via a crafted web site.