Where
-Infinity
0
Severity
10
OS Command Injection, Command Injection
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. An attack uses shell metacharacters in the senderemail parameter.

First published (updated )
Severity
9.8
EPSS
0.04%
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the uploadfile.cgi component.

First published (updated )
Severity
9.8
EPSS
0.24%
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

First published (updated )
Severity
9.8
EPSS
0.21%
Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file uploadfile.cgi. The manipulation of the argument QUERYSTRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

First published (updated )
Severity
9.8
EPSS
0.24%
Buffer Overflow
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

First published (updated )
Severity
9.8
EPSS
0.21%
Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file uploadfile.cgi. The manipulation of the argument QUERYSTRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

First published (updated )
Severity
9.8
EPSS
0.21%
Command Injection
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

UNSUPPORTED WHEN ASSIGNED A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file uploadfile.cgi. The manipulation of the argument QUERYSTRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

First published (updated )
Severity
9.8
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service.

First published (updated )
Severity
9.8
OS Command Injection, Command Injection
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

DISPUTED Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware.

1 / 2
First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

DISPUTED Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocalbuff4326, and setgetparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance.

1 / 2
First published (updated )
Severity
9.8
OS Command Injection, Command Injection
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

DISPUTED Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance.

1 / 2
First published (updated )
Severity
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found.

First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header.

First published (updated )
Severity
9.3
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:Red

Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.

First published (updated )
Severity
9.3
EPSS
0.96%
Command Injection, OS Command Injection
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:Amber

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d485731, 0122e, 0124d485731, 012501, 012502, 0125c.

First published (updated )
Severity
9.3
Buffer Overflow
AV:N/AC:M/Au:N/C:C/I:C/A:C

Stack-based buffer overflow in VATDecoder.VatCtrl.1 ActiveX control in (1) 4xem VatCtrl Class (VATDecoder.dll 1.0.0.27 and 1.0.0.51), (2) D-Link MPEG4 SHM Audio Control (VAPGDecoder.dll 1.7.0.5), (3) Vivotek RTSP MPEG4 SP Control (RtspVapgDecoderNew.dll 2.0.0.39), and possibly other products, allows remote attackers to execute arbitrary code via a long Url property. NOTE: some of these details are obtained from third party information.

First published (updated )
Severity
9
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Various VIVOTEK FD8, FD9, FE9, IB8, IB9, IP9, IZ9, MS9, SD9, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code.

First published (updated )
Severity
9
OS Command Injection, Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.

First published (updated )
Severity
9
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/deviceservice).

First published (updated )
Severity
9
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi.

First published (updated )
Severity
9
OS Command Injection
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXXBeta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices.

First published (updated )
Severity
8.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A post-authentication remote buffer overflow vulnerability exists in the /cgi-bin/admin/eventtask.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device remotely.

First published (updated )
Severity
8.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

A remote buffer overflow vulnerability exists in the /cgi-bin/dido/setdo.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device.

First published (updated )
Severity
8.8
CSRF
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF.

First published (updated )
Severity
8.7
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

First published (updated )
Severity
8.6
OS Command Injection, Command Injection
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

First published (updated )
Severity
7.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header.

First published (updated )
Severity
7.6
Buffer Overflow
AV:N/AC:H/Au:N/C:C/I:C/A:C

Stack-based buffer overflow in the Vivotek Motion Jpeg ActiveX control (aka MjpegControl) in MjpegDecoder.dll 2.0.0.13 allows remote attackers to execute arbitrary code via a long PtzUrl property value.

First published (updated )
Severity
7.5
Infoleak
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text.

First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203