See how xerox compares to other vendors in security performance
An XML External Entity (XXE) vulnerability allows malicious user to perform Server-Side Request Forgery (SSRF) via crafted XML input containing malicious external entity references.
This issue affects Xerox FreeFlow Core versions up to and including 8.0.7.
Please consider upgrading to FreeFlow Core version 8.1.0 via the software available on - https://www.support.xerox.com/en-us/product/core/downloads
In Xerox FreeFlow Core version 8.0.4, improper handling of XML input allows injection of external entities. An attacker can craft malicious XML containing references to internal URLs, this results in a Server-Side Request Forgery (SSRF).
Xerox Workplace Suite exposes sensitive secrets in clear text, both locally and remotely. This vulnerability allows attackers to intercept or access secrets without encryption
A vulnerability in Xerox Workplace Suite arises from flawed token generation and the use of hard-coded keys. These weaknesses allow attackers to predict or forge tokens, leading to unauthorized access to sensitive functions.
In Xerox Workplace Suite, an API restricted to specific hosts can be bypassed by manipulating the Host header. If the server improperly validates or trusts the Host header without verifying the actual destination, an attacker can forge a value to gain unauthorized access. This exploit targets improper host validation, potentially exposing sensitive API endpoints.
Authenticated RCE via Path Traversal
Authenticated RCE via Path Traversal
Xerox ColorQube 8580 was discovered to contain an access control issue which allows attackers to print, view the status, and obtain sensitive information.
XMPie uStore 12.3.7244.0 allows for administrators to generate reports based on raw SQL queries. Since the application ships with default administrative credentials, an attacker may authenticate into the application and exfiltrate sensitive information from the database.
Xerox VersaLink devices on specific versions of firmware before 2022-01-26 allow remote attackers to brick the device via a crafted TIFF file in an unauthenticated HTTP POST request. There is a permanent denial of service because image parsing causes a reboot, but image parsing is restarted as soon as the boot process finishes. However, this boot loop can be resolved by a field technician. The TIFF file must have an incomplete Image Directory. Affected firmware versions include xx.42.01 and xx.50.61. NOTE: the 2022-01-24 NeoSmart article included "believed to affect all previous and later versions as of the date of this posting" but a 2022-01-26 vendor statement reports "the latest versions of firmware are not vulnerable to this issue."
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 provide the ability to set configuration attributes without administrative rights.
On Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200, portions of the drive containing executable code were not encrypted thus leaving it open to potential cryptographic information disclosure.
Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200 allow an attacker to execute an unwanted binary during a exploited clone install. This requires creating a clone file and signing that file with a compromised private key.
An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) did not implement account lockout. Local account credentials may be extracted from the device via brute force guessing attacks.
Certain Xerox WorkCentre printers before 073.xxx.000.02300 do not require the user to reenter or validate LDAP bind credentials when changing the LDAP connector IP address. A malicious actor who gains access to affected devices (e.g., by using default credentials) can change the LDAP connection IP address to a system owned by the actor without knowledge of the LDAP bind credentials. After changing the LDAP connection IP address, subsequent authentication attempts will result in the printer sending plaintext LDAP (Active Directory) credentials to the actor. Although the credentials may belong to a non-privileged user, organizations frequently use privileged service accounts to bind to Active Directory. The attacker gains a foothold on the Active Directory domain at a minimum, and may use the credentials to take over control of the Active Directory domain. This affects 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices.
Xerox AltaLink C8035 printers allow CSRF. A request to add users is made in the Device User Database form field to the xerox.set URI. (The frmUserName value must have a unique name.)
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability.
SQL injection vulnerability in summary.php in Xerox Fiery Webtools allows remote attackers to execute arbitrary SQL commands via the select parameter.
The Xerox Phaser 8400 allows remote attackers to cause a denial of service (reboot) via an empty UDP packet to port 1900.
Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allows remote attackers to download the audit log and obtain potentially sensitive information via unspecified vectors.
The Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allows remote attackers to execute arbitrary commands via unspecified vectors involving "command injection" in (1) the TCP/IP hostname, (2) Scan-to-mailbox folder names, and (3) certain parameters in the Microsoft Networking configuration. NOTE: vector 1 might be the same as CVE-2006-5290.
Unspecified vulnerability in the Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allows remote attackers to bypass authentication controls via unknown vectors.
Multiple unspecified vulnerabilities in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allow remote attackers to have an unspecified impact via unspecified vectors relating to "HTTP Security issues."
Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allow remote attackers to gain access via unspecified vectors related to "browser permissions."
The SNMP implementation in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 does not generate authentication failure traps, which allows remote attackers to more easily gain system access and obtain sensitive information via a brute force attack.
Web services in Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 do not require HTTPS, which allows remote attackers to obtain sensitive information by sniffing the unencrypted HTTP traffic.
ops3-dmn in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allows attackers to cause a denial of service (application crash and core dump) via a certain PS file.
The ESS/ Network Controller and MicroServer Web Server components of Xerox WorkCentre and WorkCentre Pro 232, 238, 245, 255, 265 and 275 allow remote attackers to bypass authentication and execute arbitrary code via "WebUI command injection on TCP/IP hostname."