Where
AND
-Infinity
0
Severity
9.8
Malicious File Upload
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess/SCADA  is vulnerable to unrestricted file upload, which may allow an attacker to remotely execute arbitrary code.

Remedy

Advantech recommends users apply the following mitigations and update to WebAccess/SCADA: Version 9.2.2 https://www.advantech.com/en-us/support/details/installation .
First published (updated )
Severity
9.1
Path Traversal
AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H

Advantech WebAccess/SCADA is vulnerable to directory traversal, which may allow an attacker to delete arbitrary files.

Remedy

Advantech recommends users apply the following mitigations and update to WebAccess/SCADA: Version 9.2.2 https://www.advantech.com/en-us/support/details/installation .
First published (updated )
Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent client could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.

1 / 2
First published (updated )
Severity
9.8
Code Injection
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.

Remedy

Advantech recommends WebAccess/SCADA users upgrade to v9.1.4 https://www.advantech.com/en/support/details/installation .
First published (updated )
Severity
9.8
Malicious File Upload
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.

Remedy

Advantech recommends WebAccess/SCADA users upgrade to v9.1.4 https://www.advantech.com/en/support/details/installation .
First published (updated )
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Severity
9.8
Buffer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).

First published (updated )
Severity
9
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.

First published (updated )
Severity
9.8
Buffer Overflow
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple stack-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.

1 / 9
First published (updated )
Severity
9.8
Buffer Overflow, Integer Overflow
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple heap-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.

1 / 7
First published (updated )
Severity
9.8
Path Traversal
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control.

1 / 2
First published (updated )
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Severity
9.8
Path Traversal
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control.

1 / 4
First published (updated )
Severity
9.8
Out-of-bounds Read
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An improper validation vulnerability exists that could allow an attacker to inject specially crafted input into memory where it can be executed.

1 / 2
First published (updated )
Severity
9.8
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.

First published (updated )
Severity
9.8
SQL Injection
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.

First published (updated )
Severity
9.8
Path Traversal
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

In Advantech WebAccess versions V8.220170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to execute arbitrary code.

First published (updated )
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GpsET200 device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-622
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GpsET200 device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of IOCTL 0x00013c77 in BwWebSvc.dll. The issue results from the lack of proper validation of user-supplied data, which can trigger an overflow of a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-616
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of IOCTL 0x00013c77 in BwWebSvc.dll. The issue results from the lack of proper validation of user-supplied data, which can trigger an overflow of a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00002723 in DrawSrv.dll. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-603
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00002723 in DrawSrv.dll. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OPCUA device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OPCUA device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-624
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00002723 in ViewSrv.dll. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-593
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00002723 in ViewSrv.dll. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the BwTCPIP device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the BwTCPIP device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-621
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00005227 in DATACORE.exe. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of IOCTL 0x00005227 in DATACORE.exe. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-592
Severity
9.8
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. Authentication is not required to exploit this vulnerability. The specific flaw exists within the BwBacNetJ device driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of Administrator.

Advisory
ZDI-20-619
Free Weekly Intel

Don't miss critical vulnerabilities

Join thousands of security professionals who receive our weekly digest of trending CVEs, zero-days, and exploited vulnerabilities.

No spam. Unsubscribe anytime.

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203