Where
AND
-Infinity
0
Severity
5.5
AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Impact

CiliumNetworkPolicys which use egress.toGroups.aws.securityGroupsIds to reference AWS security group IDs that do not exist or are not attached to any network interface may unintentionally allow broader outbound access than intended by the policy authors. In such cases, the toCIDRset section of the derived policy is not generated, which means outbound traffic may be permitted to more destinations than originally intended.

Patches

This issue has been patched in:

Cilium v1.18.4 Cilium v1.17.10 Cilium v1.16.17

This issue affects:

- Cilium v1.18 between v1.18.0 and v1.18.3 inclusive - Cilium v1.17 between v1.17.0 and v1.17.9 inclusive - Cilium v1.16.16 and below

Workarounds

There is no workaround to this issue.

Acknowledgements

The Cilium community has worked together with members of Isovalent to prepare these mitigations. Special thanks to @SeanEmac for reporting this issue and to @fristonio for the patch.

For more information

If you think you have found a vulnerability affecting Cilium, we strongly encourage you to report it to our security mailing list at security@cilium.io. This is a private mailing list for the Cilium security team, and your report will be treated as top priority.

1 / 2
Source: GitHub
First published (updated )
Severity
4.3
EPSS
0.02%
AV:L/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N

Impact

For Cilium users who: - Use Gateway API for Ingress for some services AND - Use LB-IPAM or BGP for LB Service implementation AND - Use network policies to block egress traffic from workloads in a namespace to workloads in other namespaces

Egress traffic from workloads covered by such network policies to LoadBalancers configured by Gateway resources will incorrectly be allowed.

LoadBalancer resources not deployed via a Gateway API configuration are not affected by this issue.

Patches

This issue was fixed by https://github.com/cilium/proxy/pull/1172.

This issue affects:

- Cilium v1.15 between v1.15.0 and v1.15.14 inclusive - Cilium v1.16 between v1.16.0 and v1.16.7 inclusive - Cilium v1.17 between v1.17.0 and v1.17.1 inclusive

This issue is fixed in:

- Cilium v1.15.15 - Cilium v1.16.8 - Cilium v1.17.2

Workarounds

A Clusterwide Cilium Network Policy can be used to work around this issue for users who are unable to upgrade. An outline of such a policy is provided below:

apiVersion: "cilium.io/v2" kind: CiliumClusterwideNetworkPolicy metadata: name: "workaround" spec: endpointSelector: matchExpressions: - key: reserved:ingress operator: Exists ingress: - fromEntities: - world

- The policy opens up connectivity from all locations outside the cluster into the Cilium Ingress Gateway. - The policy establishes a default deny for all other traffic towards the Cilium Ingress Gateway, including all in-cluster sources. - It is possible to tailor the policy to more narrowly allow inbound traffic while creating a default deny posture for traffic between namespaces. Users should edit the policy to bring it in line with the security requirements particular to their environments.

Acknowledgements

The Cilium community has worked together with members of the Isovalent team to prepare these mitigations. Special thanks to @jrajahalme for the fix.

For more information

If you think you have found a vulnerability affecting Cilium, we strongly encourage you to report it to our security mailing list at security@cilium.io. This is a private mailing list for the Cilium security team, and your report will be treated as top priority.

1 / 2
Source: GitHub
First published (updated )
Severity
4.7
EPSS
0.02%
AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N

Impact

Node based network policies (fromNodes and toNodes) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in fromNodes and toNodes sections of network policies. Node based network policy is disabled by default in Cilium.

Patches

This issue was fixed by https://github.com/cilium/cilium/pull/36657.

This issue affects:

- Cilium v1.16 between v1.16.0 and v1.16.7 inclusive - Cilium v1.17 between v1.17.0 and v1.17.1 inclusive

This issue is fixed in:

- Cilium v1.16.8 - Cilium v1.17.2

Workarounds

Users can work around this issue by ensuring that the labels used in fromNodes and toNodes fields are used exclusively by nodes and not by other endpoints.

Acknowledgements

The Cilium community has worked together with members of Isovalent to prepare these mitigations. Special thanks to @oblazek for reporting and fixing this issue.

For more information

If you think you have found a vulnerability affecting Cilium, we strongly encourage you to report it to our security mailing list at security@cilium.io. This is a private mailing list for the Cilium security team, and your report will be treated as top priority. Please also address any comments or questions on this advisory to the same mailing list.

1 / 2
Source: GitHub
First published (updated )

Contact

SecAlerts Pty Ltd.
132 Wickham Terrace
Fortitude Valley,
QLD 4006, Australia
info@secalerts.co
By using SecAlerts services, you agree to our services end-user license agreement. This website is safeguarded by reCAPTCHA and governed by the Google Privacy Policy and Terms of Service. All names, logos, and brands of products are owned by their respective owners, and any usage of these names, logos, and brands for identification purposes only does not imply endorsement. If you possess any content that requires removal, please get in touch with us.
© 2026 SecAlerts Pty Ltd.
ABN: 70 645 966 203, ACN: 645 966 203