Hospital Queuing Management developed by Advantech has a Sensitive Data Exposure vulnerability, allowing unauthenticated remote attackers to access a specific URL to obtain API documentation.
Successful exploitation of the SQL injection vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL commands on the vulnerable service when it is exposed to the Internet, potentially affecting data confidentiality, integrity, and availability. Users and administrators of affected product versions are advised to update to the latest versions immediately.
Advantech WebAccess/SCADA is vulnerable to unrestricted file upload, which may allow an attacker to remotely execute arbitrary code.
Advantech WebAccess/SCADA is vulnerable to directory traversal, which may allow an attacker to delete arbitrary files.
Advantech WISE-DeviceOn Server versions prior to 5.4 contain a hard-coded cryptographic key vulnerability. The product uses a static HS512 HMAC secret for signing EIRMMToken JWTs across all installations. The server accepts forged JWTs that need only contain a valid email claim, allowing a remote unauthenticated attacker to generate arbitrary tokens and impersonate any DeviceOn account, including the root super admin. Successful exploitation permits full administrative control of the DeviceOn instance and can be leveraged to execute code on managed agents through DeviceOn’s remote management features.
Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.
Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘ztpsearchvalue’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘ztpconfigid’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for the exfiltration of user data, included clear text passwords.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘searchterm’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘getInventoryReportData’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.
Successful exploitation of the vulnerability could allow an unauthenticated attacker to upload firmware through a public update page, potentially leading to backdoor installation or privilege escalation.
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capturepackages" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restoreconfigfromutility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backupconfigtoutility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlanscan" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfgcmdsetethconf" operation.
Advantech R-SeeNet v2.4.23 allows an unauthenticated remote attacker to read from and write to the snmpmon.ini file, which contains sensitive information.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the ping tool of the web-interface.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the device name field of the web-interface.
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent client could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
Advantech R-SeeNet versions 2.4.22
is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.
The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.
The affected product is vulnerable to directory traversal, which may allow an attacker to access unauthorized files and execute arbitrary code.
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.